The subtask receives an error: Delete Transport Node Configuration from ESXi Host(s) Fails when removing a host from the SDDC manager: Description Delete Transport Node Configuration from ESXi Host(s) Progress Messages Transport node deletion operation failed ErrorMessage: Transport node deletion operation failed Remediation Message:Reference Token: 75FCTF
This failure occurs when a Transport Node Profile is assigned in NSX-T at the cluster level. com.vmware.vapi.std.errors.InvalidRequest: InvalidRequest (com.vmware.vapi.std.errors.invalid_request) => { messages = [], data = struct => {error_message=Cannot delete a transport node 81923994-f3b2-4bbc-a7ac-cf4afe2d7436 which is part of TNP applied compute collection 1a38bad7-a2e0-411e-b7fc-daa2282879ad:domain-c11. Please use the object name or UUID in Global Search to find all linked objects., httpStatus=BAD_REQUEST, error_code=9411, module_name=NsxSwitching service}, errorType = INVALID_REQUEST } InvalidRequest (com.vmware.vapi.std.errors.invalid_request) => { messages = [], data = struct => {error_message=Cannot delete a transport node 81923994-f3b2-4bbc-a7ac-cf4afe2d7436 which is part of TNP applied compute collection 1a38bad7-a2e0-411e-b7fc-daa2282879ad:domain-c11. Please use the object name or UUID in Global Search to find all linked objects., httpStatus=BAD_REQUEST, error_code=9411, module_name=NsxSwitching service}, errorType = INVALID_REQUEST }
1. Remove the Transport Node Profile From NSX-T UI: Log in to the NSX-T UI as admin (NSX-T Data Center 3.2.2) Go to: System > Fabric > Hosts and select the Cluster tab (NSX-T Data Center 3.2.1 or earlier) Go to: System > Fabric > Nodes > Host Transport Nodes and from the Managed by dropdown menu, select a vCenter Server. Select the Cluster that this node is in > Actions > Detach Transport Node Profile . Make note of the profile that is applied, under the "Applied Profile" section. This should have no impact to production. 2. Restart the Node removal operation from SDDC Manager. 3. Once complete, reapply the Transport Node profile to the cluster level: Log in to the NSX-T UI as admin NSX-T Data Center 3.2.2) Go to: System > Fabric > Hosts and select the Cluster tab (NSX-T Data Center 3.2.1 or earlier) Go to: System > Fabric > Nodes > Host Transport Nodes and from the Managed by dropdown menu, select a vCenter Server. Select the Cluster > Configure NSX > on the selected Transport Node Profile dropdown, select previously applied profile > Save . This says reconfiguring the nodes, but it verifies that the necessary VIB and vSwitch information is correct.
Click on a version to see all relevant bugs
Dell Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.