The NetWorker vProxy recover session log shows: 159373:nsrvproxy_recover: vProxy Log: ####-##-#####:##:### ERROR: [75] Error registering VM: ServerFaultCode: Permission to perform this operation was denied. 159373:nsrvproxy_recover: vProxy Log: ####-##-#####:##:### ERROR: [75] Error in registering VM "[####l-####-SAN-Datastore] ###_1/###_1.vmx". "ServerFaultCode: Permission to perform this operation was denied." 159373:nsrvproxy_recover: vProxy Log: ####-##-#####:##:### WARN: [75] RecoverVMSessions "####-###-###-###-113093c9524a" cleaning up running recover session due to error. 159373:nsrvproxy_recover: vProxy Log: ####-##-#####:##:### INFO: [75] Successfully removed folder/file "[####l-####-SAN-Datastore] ###_1". 159373:nsrvproxy_recover: vProxy Log: ####-##-#####:##:### INFO: [75] Disconnected from session on vCenter '####.###.###'. 159373:nsrvproxy_recover: vProxy Log: ####-##-#####:##:### ERROR: [75] Failed to recover to a new VM. ServerFaultCode: Permission to perform this operation was denied. 152793:nsrvproxy_recover: vProxy Log Ends ================================================= 153335:nsrvproxy_recover: Virtual machine recovery failed: vProxy recovery failed with error message: Session "####-###-###-###-113093c9524a" failed. Error: ServerFaultCode: Permission to perform this operation was denied.. vProxy Recover Log locations /opt/emc/vproxy/runtime/logs/vrecoverd /opt/emc/vproxy/runtime/logs/recycle/vrecoverd
The VMware vCenter has the "Deployed in Cloud" checkbox Enabled in NetWorker; however, the vCenter server is not deployed in Cloud.
Go to NetWorker Management Console (NMC) user interface Launch NetWorker Administration Window. Right Click vCenter Click " Modify vCenter ." Clear the " Deployed in Cloud " checkbox. Perform the VM restore again, and it completes successfully. Perform VM backups as well to ensure no impact to data protection. Alternatively, this change can be performed from a nsradmin prompt on the NetWorker server: [root@nsr ~]# nsradmin NetWorker administration program. Use the "help" command for help, "visual" for full-screen mode. nsradmin> show name; cloud nsradmin> print type: nsr hypervisor name: vcsa.amer.lan; cloud: Yes; nsradmin> update cloud: No cloud: No; Update? y updated resource id 177.0.110.157.0.0.0.0.243.35.70.103.192.168.9.150(19710) nsradmin> print name: vcsa.amer.lan; cloud: No; nsradmin> quit
Click on a version to see all relevant bugs
Dell Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.