Loading...
Loading...
++Link going down as Link failure and while reset and flap it shows link is down (None) ++Ethpm shows PORT_FSM_ACTION_INIT and TAG_TXN_GRCFL_CLOSE ++ELTM Logs shows eltm_send_ethpm_pre_cfg_response_cb ++ Link(interface) was up and carying traffic before ++ Link flaps seen
1) Bounce the interface ethX/Y [Shut and no shut] but no change 2) SFP is detecting on interface ETHX/X and no alarms on Transceiver detail [No TX and RX low value] 3) Made interface eth1/9 default and reconfigured but link remains down [Link not connected] 3) Move the SFP and cable from interface(X/X) to another(X/Y) and letter another(X/Z) but no change Link still down [ link not connected] 4) Move the SFP and cable to another switch and Links comes up [This state no issue on Far-end] 5) Move the SFP and cable back to Switch ethX/Y but its again shows down [Link not connected] 6) Move the SFP and cable from ETHX/Y to ETHX/X and reloaded the switch
Reload of switch
PSIRT Evaluation: The Cisco PSIRT has evaluated this issue and determined it does not meet the criteria for PSIRT ownership or involvement. This issue will be addressed via normal resolution channels. If you believe that there is new information that would cause a change in the severity of this issue, please contact psirt@cisco.com for another evaluation. Additional information on Cisco's security vulnerability policy can be found at the following URL: http://www.cisco.com/en/US/products/products_security_vulnerability_policy.html
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.