Nexus 9K platforms have 40G ports. When you breakout one of the 40G ports into 4x10G ports with a QSFP breakout cable, not all of the subinterfaces can be added to a port channel.
40G port broken out into 4x10G subinterfaces on the Nexus 9K.
+ Configure "no buffer-boost" on all of the subinterfaces. This enables the channel-group config to go through. Note: Using the "force" keyword on the port-channel is does not enable all the interfaces to be added to the port-channel, even though the error suggests this: ** You can use force option to override the port's parameters ** (e.g. "channel-group X force"
Nexus 9K platforms have 40G ports. When you breakout one of the 40G ports into 4x10G ports with a QSFP breakout cable, not all of the subinterfaces can be added to a port channel. The error message shown is the following: F340-12-21-N9K-C9332PQ-1(config-if)# channel-group 99 mode active command failed: port not compatible [Buffer boost] ** You can use force option to override the port's parameters ** (e.g. "channel-group X force") ** Use "show port-channel compatibility-parameters" to get more information on failure