Translations [sys_translated_text] entries are not moving when importing customization changes from source control or via update sets. Steps to Reproduce 1) Create a record producer in scope Human Resources: Core. 2) Confirm the RP XML and the sys_translated_text table have entries for the RP name, Short Description and description. 3) Go to Studio - select Human Resources: Core - Source Control - Commit Changes o Select relevant ones and submit 4) Go to another instance 5) Go to studio - select Human Resources: Core - Apply remote changes to reset the app - Change branch to newest one (latest date) - Wait for the branch change to terminate. 6) Then go to sys_translated_text and try to find the records with the sysIDs in the highlighted section, for example f8cb4ddd93859a90b5b3f4ed1dba1087. Expected Outcome: A record is found and when viewing the Item of the portal in French, all text is displayed in French. Workaround 1. Workaround is to manually load the missing sys_translated_text records 2. In some cases it may be needed to add the "serializer=com.glide.script.TranslatedTextXMLSerializer" attribute to a custom translated html field in order for the translation to be captured as customization (sys_update_xml).