The HPE QLogic Fibre Channel Host Bus Adapter (HBA) firmware version 2025.05.01 encounters a dependency error during installation on Red Hat Enterprise Linux (RHEL) 10. This issue arises when using Smart Update Manager (SUM), Service Pack for ProLiant (SPP), OneView (OV), or Compute Ops Management (COM) on any HPE ProLiant servers and HPE Synergy compute modules equipped with the HBAs specified in the Scope section.Dependency error message:error: Failed dependencies:libcrypt.so.1()(64bit) is needed by firmware-fc-sy-qlogic-2025.05.01-1.1.x86_64libcrypt.so.1(GLIBC_2.2.5)(64bit) is needed by firmware-fc-sy-qlogic-2025.05.01-1.1.x86_64SPP Dependency error message Example:NOTE: The same error might be seen during installation of the QConvergeConsole Command Line Utility (QCC CLI) package.
This issue affects all HPE ProLiant servers and HPE Synergy Compute Modules configured with any of the following fibre channel adapters:HPE SN1100Q 16GB Dual Port PCIe Fibre Channel Host Bus AdapterHPE SN1100Q 16GB Single Port PCIe Fibre Channel Host Bus AdapterHPE SN1600Q 32Gb Single Port Fibre Channel Host Bus AdapterHPE SN1600Q 32Gb Dual Port Fibre Channel Host Bus AdapterHPE SN1610Q 32Gb Dual Port Fibre Channel Host Bus AdapterHPE SN1610Q 32Gb Single Port Fibre Channel Host Bus AdapterHPE SN1700Q 64Gb Dual Port Fibre Channel Host Bus AdapterHPE SN1700Q 64Gb Single Port Fibre Channel Host Bus AdapterHPE Synergy 3830C 16G Fibre Channel Host Bus AdapterHPE Synergy 5830C 32Gb Fibre Channel Host Bus Adapter
Refer to the Workaround below as there are currently no plans to resolve this issue.AS a workaround, to address the dependency error encountered during the installation of the HPE Firmware Flash for QLogic Fibre Channel HBAs, as detailed in the Description section, install the libxcrypt-compat RPM package (libxcrypt-compat-4.4.36-10.el10.x86_64.rpm) before deployment.This workaround is necessary to ensure compatibility and successful installation on Red Hat Enterprise Linux (RHEL) 10. Refer to theRed Hat Knowledgebase articlefor further details.Disclaimer: One or more of the links above will take you outside the HPE website. HPE is not responsible for content outside of its domain.
Operating Systems Affected:Red Hat Enterprise Linux 10
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.