A value set for the cxi_core untagged_eth_pcp option in cxi_core.conf does not get applied. The option setting is not picked up and the resulting value remains at '-1'.# cat /sys/module/cxi_core/parameters/untagged_eth_pcp-1
This customer advisory applies to Slingshot Host Software version 2.2 and 11.0 in CSM and HPCM environment.
The rxe_init.sh script must be replaced with an updated version. The replacement rxe_init.sh script removes the "untagged_eth_pcp" cxi_core parameter check. The configuration of the untagged ethernet pcp was moved to the QoS profile, and the parameter no longer reflects the actual value being used.To install the rxe_init.sh script:1. On each node using RXE, copy the rxe_init.sh script providedto /usr/bin/2. Ensure that the rxe_init.sh file has user/group owners of 'root'.3. Ensure that the file has executable permissions.The replacement script will now be used in place of the prior /usr/bin/rxe_init.sh script that was installed by the cray-rxe-driver rpm.Note: There are two versions of the modified rxe_init.sh script. One for the 2.2.0 release and one for the 11.0 release. The modified rxe_init.sh scripts are not the same. Be sure to install the script that matches the installed system release version.The respective rxe_init.sh scripts are available from the following links:Script for Slingshot Host Software 2.2.0https://downloads.hpe.com/pub/softlib2/software1/cd/p1078951391/v258563/rxe_init.shScript for Slingshot Host Software 11.0.0https://downloads.hpe.com/pub/softlib2/software1/cd/p1078951391/v258764/rxe_init.sh
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.