For any Rev B1 (or earlier) NVIDIA InfiniBand NDR 64-port OSFP and NVIDIA InfiniBand HDR 40-port QSFP56 switches listed in the Scope section below, the following issues may occur:In rare instances and after rebooting, a group of 8 or 16 network ports may change to a link down state. Performing a power cycle may restore the affected network ports.In rare instances, the I2C bus may report errors when trying to access the thermal sensors. This issue does not affect switch functionality.In rare instances, false "fan not present" alerts may be reported. This issue does not affect switch functionality.An interference in the AC line may cause an incorrect reset sequence. As a result, all ports may change to a link down state. Performing a power cycle may restore the affected network ports. Switches connected to a single power supply will be more susceptible to this issue.In rare instances, the management module of managed switches may change to a fatal state (MGMT Module in fatal state), as shown below.ERR 2024/05/15 18:39:36 : MGMT Module in fatal stateERR 2024/05/15 19:39:52 : MGMT Module in fatal stateERR 2024/05/15 20:40:01 : MGMT Module in fatal state
In the scenario described above, the following Rev B1 (or earlier) NDR switches and HDR switches:NVIDIA InfiniBand NDR 64-port OSFP Managed Power to Connector Airflow Switch (P45692-B21)NVIDIA InfiniBand NDR 64-port OSFP Power to Connector Airflow Switch (P45691-B21)NVIDIA InfiniBand HDR 40-port QSFP56 Managed Back to Front Airflow Switch (P06249-B21)NVIDIA InfiniBand HDR 40-port QSFP56 Unmanaged Back to Front Airflow Switch (P10774-B21)
If these issues have already occurred, remove the AC power from the switch, and wait 2 to 5 minutes to drain/reset the CPLD.To avoid these issues, perform the following steps:Remove the AC power from the switch, and wait 2 to 5 minutes to drain/reset the CPLD.Update the MAIN CPLD to version CPLD000324_REV400 (or later).MAIN CPLD CPLD000324_REV400 includes the following versions:Port CPLD: CPLD000268_REV700MNG CPLD: CPLD000232_REV700For NVIDIA InfiniBand NDR switches, CPLD000324_REV400 and detailed update instructions can be found at the below link.NVIDIA updateswitchcpld toolDisclaimer:One or more of the above links redirects outside the HPE website. HPE is not responsible for content outside of its domain.For NVIDIA InfiniBand HDR switches, use the following update tool:updateswitchcpld_v1.7updateswitchcpld_v1.7.sigRevision HistoryDocument VersionRelease DateDetails3August 29, 2025The Resolution section has been updated with the CPLD update tool for NVIDIA InfiniBand HDR switches.2May 15, 2025The advisory has been updated to include NVIDIA InfiniBand HDR 40-port QSFP56 Switches and additional information.1September 17, 2024Original Document Release.
Operating Systems Affected:Not Applicable
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.