On any HPE systems with iLO 6, a higher than normal fan speed, a higher fan speed than normal operation while using Pass Through Board (PTB), on-board M.2 with Micron M.2 drive, or SK hynix drive may occur. The M.2 sensor will not display on Integrated Lights-Out 6 (iLO 6) web interface when this occurs.The functionality of the server is not affected.Samsung drive - M.2 sensor displayed:Micron drive - M.2 sensor not displayed:iLO 6 accesses the M.2 temperature through i2c which is not support for the Micron drive. Therefore, no temperature reading on the Micron drive causes the system to call a backup sensor to maintain sufficient cooling capability.
Any HPE systems with iLO 6 configured with specific NVMe M.2 drive or SK Hynix drive.
The functionality of the server is not affected. Backup sensor will keep sufficient drive cooling performance.Document VersionRelease DateDetails2May 29, 2025Added SK Hynix as affected.1March 14, 2023Original Document Release.
Operating Systems Affected:Not Applicable