Document Version Release Date Details 2 March 31, 2023 Updated "port discovery information" paragraph 1 April 4, 2022 Original document release HPE Superdome Flex 280 Servers configured with SmartRAID 31xx controllers may not find the logical drive volume after a Smart RAID firmware update or card replacement. On rare occasions, SmartRAID 31xx controllers may experience a factory reset during the firmware update process resulting in port discovery mode set to Serial GPIO (SGPIO). SmartRAID 31xx controllers in HPE Superdome Flex 280 servers require the port discovery mode to be set to UBM as this enables the controller to communicate with the storage backplane to properly detect the drives and any existing RAID configurations. However, SmartRAID 31xx controllers that have been factory reset or are new replacement cards are set in SGPIO mode by default. Note : When the port discovery mode is set to SGPIO mode, dual-port SAS drives may also display duplicated entries in the list of connected drives. This occurs because each port of the drive is displayed as a separate device to the SmartRAID 31xx controller in SGPIO mode. How to display the "port discovery mode" setting: From the Unified Extensible Firmware Interface (UEFI) Device Manager, select the Smart RAID controller. Select Configure Controller Settings > Configure Port Discovery Protocol Check the mode displayed: Universal Backplane Management (UBM) or SGPIO. OR Using the Smart Storage Administrator Command Line Interface (SSACLI) or SSA GUI tools. Run: SSACLI ctrl <target> show config detail where <target> is one of [all|slot=#|serialnumber=#] The output will display either SGPIO or UBM
Any SmartRAID 3154-16i, 3154-24i, and 3162-8i/e controllers used in an HPE Superdome Flex 280 servers.
SmartRAID 31xx controllers in Superdome Flex 280 servers require the port discovery mode to be set to UBM as this enables the controller to communicate with the storage backplane to properly detect the drives and any existing RAID configurations. However, in rare instances SmartRAID 31xx controllers may experience factory reset after a firmware update. Additionally new replacement cards are set to SGPIO mode by default. Customers may choose to delay deploying SmartRAID 31xx firmware updates until this issue is addressed in a future release (Q4 2023). Outlined below are the steps to properly set the Port Discovery Mode. Backing up important data for safekeeping is a recommended best practice prior to updating or replacing storage controllers. Change the "port discovery protocol" setting to UBM (if set to SGPIO) by performing either of the following: UEFI method Go to UEFI Device Manager and select the SmartRAID controller. Configure Controller Settings > Configure Port Discovery Protocol > Set Port Discovery Protocol Change mode for each controller connector port to <UBM> [Submit Changes] > [Back to Main Menu] Repeat for other SmartRAID internal storage controllers. Reset (from the UEFI main menu) OR OS utility method Install SSACLI if not already installed from the HPE Superdome Flex I/O Service Pack Run the following command: ssacli ctrl all show Run the following command for each controller slot listed by the previous command: ssacli ctrl slot=#### modify discoveryprotocol=ubm Reboot the OS Link to the HPE Superdome Flex I/O Service Pack . The port discovery setting can be checked using the customer tools SSACLI or SSA GUI. Below is an example from the SSACLI command "ctrl <target> show config detail" run on a 3154-24i: where <target> is one of [all|slot=#|serialnumber=#] Port Name: CN0 Port ID: 0 Port Mode: RAID Port Connection Number: 0 SAS Address: 50000D1F00948800 Port Location: Internal Port Phy Count: 4 Current Backplane Discovery Protocol: UBM Note: Six entries similar to the above will be displayed for a 3154-24i (6 ports), 4 entries for a 3154-16i (4 ports), 2 entries for a 3162-8i/e (2 ports). RECEIVE PROACTIVE UPDATES : Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively in your e-mail through HPE Support Alerts. Sign up for Support Alerts at the following URL: Proactive Updates Subscription Form. NAVIGATION TIP: For hints on navigating HPE.com to locate the latest drivers, patches and other support software downloads, refer to the Navigation Tips document. SEARCH TIP: For hints on locating similar documents on HPE.com, refer to the Search Tips document