Document VersionRelease DateDetails404/01/2021Added Note: with additional RPMs to Description.302/20/2020Added Red Hat Enterprise Linux 8 and SUSE Linux Enterprise Server 15 as affected Operating Systems and added HPE Synergy 6410C 25/50Gb Ethernet Adapter as an affected product.206/21/2019No update to Customer Advisory except created new Customer Advisory number. Supersedes c05332913.112/15/2016Original Document Release.The Mellanox RDMA over Converged Ethernet (RoCE) driver component includes both kernel space and user space components.Below is an example for Red Hat Enterprise Linux 6.8:kmod-mlnx-ofa_kernel-3.3-OFED.3.3.1.0.0.1.gf583963.rhel6u8.x86_64.rpm (Kernel modules RPM)mlnx-ofa_kernel-3.3-OFED.3.3.1.0.0.1.gf583963.2.rhel6u8.x86_64.rpm (RPM containing user space libraries).The RoCE user space library RPM (mlnx-ofa_kernel) is known to conflict with the OpenMPI RPMs available with the Red Hat Enterprise Linux and SUSE Linux Enterprise Server distributions.When installing Mellanox RoCE driver packages on an HPE ProLiant server running Red Hat Enterprise Linux 6, Red Hat Enterprise Linux 7, Red Hat Enterprise Linux 8, SUSE Linux Enterprise Server 11, SUSE Linux Enterprise Server 12, or SUSE Linux Enterprise Server 15 and configured with any of the devices listed in the Scope section below, using a command similar to the following:#rpm -Uvh kmod-mlnx-ofa_kernel-3.3-OFED.3.3.1.0.0.1.gf583963.rhel6u8.x86_64.rpmmlnx-ofa_kernel-3.3-OFED.3.3.1.0.0.1.gf583963.2.rhel6u8.x86_64.rpmThe following messages may be displayed if the OpenMPI RPMs are installed:error:Failed dependencies:libibcm.so.1()(64bit) is needed by(installed) openmpi-1.4-psm-1.4.3-5.el6.x86_64libibcm.so.1()(64bit) is needed by(installed) openmpi-1.4-1.4.3-5.el6.x86_64Note: On SUSE Linux Enterprise Server 15 SPx full package installation, the mlnx-ofa_kernel RPM is known to conflict with the following RPMs in addition to the OpenMPI RPM:mvapich2slurmlibdat2libdpdk
Any HPE ProLiant server running Red Hat Enterprise Linux 6, Red Hat Enterprise Linux 7, Red Hat Enterprise Linux 8, SUSE Linux Enterprise Server 11, SUSE Linux Enterprise Server 12 or SUSE Linux Enterprise Server 15 and configured with any of the following devices:HPE Ethernet 25Gb 2-port 640SFP28 Adapter (HPE Part Number: 817753-B21)HPE Ethernet 25Gb 2-port 640FLR-SFP28 Adapter (HPE Part Number: 817749-B21)HPE InfiniBand EDR/Ethernet 100Gb 1-port 840QSFP28 Adapter (HPE Part Number: 825110-B21)HPE InfiniBand EDR/Ethernet 100Gb 2-port 840QSFP28 Adapter (HPE Part Number: 825111-B21)HP Ethernet 10Gb 2-port 546SFP+ Adapter (HP Part Number: 779793-B21)HP Ethernet 10Gb 2-port 546FLR-SFP+ Adapter (HP Part Number: 779799-B21)HP InfiniBand QDR/Ethernet 10Gb 2-port 544+M Adapter (HP Part Number: 764282-B21)HP InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+M Adapter (HP Part Number: 764283-B21)HP InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+QSFP Adapter (HP Part Number: 764284-B21)HP InfiniBand FDR/Ethernet 10Gb/40Gb 2-port 544+FLR-QSFP Adapter (HP Part Number: 764285-B21)HP InfiniBand QDR/Ethernet 10Gb 2-port 544+FLR-QSFP Adapter (HP Part Number: 764286-B21)HP InfiniBand QDR/EN 10Gb Dual Port 544M Adapter (HP Part Number: 644160-B21)HP InfiniBand FDR/EN 10/40Gb Dual Port 544M Adapter (HP Part Number: 644161-B21/644161-B22)HP InfiniBand FDR/Ethernet 10/40Gb 2-port 544QSFP Adapter (HP Part Number: 649281-B21)HP InfiniBand FDR/Ethernet 10/40Gb 2-port 544FLR-QSFP Adapter (HP Part Number: 649282-B21)HP InfiniBand QDR/Ethernet 10Gb 2-port 544FLR-QSFP Adapter (HP Part Number: 649283-B21)HP Infiniband QDR/Ethernet 10Gb 2P 544i Adapter (HP ProLiant SL4545 G7 Server and HP ProLiant SL4540 Gen8 Server LOM)HPE InfiniBand EDR 100Gb 1-port 841QSFP28 Adapter (HPE Part Number: 872725-B21)HPE InfiniBand EDR/Ethernet 100Gb 2-port 841QSFP28 Adapter (HPE Part Number: 872726-B21)HPE InfiniBand FDR/Ethernet 40/50Gb 2-port 547FLR-QSFP Adapter (HPE Part Number: 879482-B21)HPE InfiniBand HDR/Ethernet 200Gb 1-port 940QSFP56 x16 Adapter (HPE Part Number: P06154-B21)HPE InfiniBand HDR100/Ethernet 100Gb 1-port 940QSFP56 x16 Adapter (HPE Part Number: P06250-B21)HPE InfiniBand HDR100/Ethernet 100Gb 2-port 940QSFP56 x16 Adapter (HPE Part Number: P06251-B21)HPE Ethernet 10Gb 2-port 548SFP+ Adapter (HPE Part Number: P11338-B21)HPE Ethernet 100Gb 1-port 842QSFP28 Adapter (HPE Part Number: 874253-B21)HPE Synergy 6410C 25/50Gb Ethernet Adapter (HPE Part Number: 868779-B21)Note:The list of affected adapters is current as of the Release Date of this Customer Advisory revision. The issue occurs with any future Mellanox adapter supporting Mellanox RDMA over Converged Ethernet (RoCE) driver component. Similarly, all versions of Mellanox RDMA over Converged Ethernet (RoCE) driver component RPMs are affected.
This is a known behavior. Insure that the OpenMPI RPMs from the Linux distribution are not installed on the target node prior to the installation of "mlnx-ofa_kernel."If the RPMs are already installed, uninstall any OpenMPI distribution RPMs before installing HPE MellanoxRoCE driver packages using a command similar to the following:# rpm -e openmpi-1.10-1.10.2-2.el6.x86_64RECEIVE PROACTIVE UPDATES: Receive support alerts (such as Customer Advisories), as well as updates on drivers, software, firmware, and customer replaceable components, proactively via e-mail through HPE Subscriber's Choice. Sign up for Subscriber's Choice at the following URL:Proactive Updates Subscription Form.NAVIGATION TIP: For hints on navigating HPE.com to locate the latest drivers, patches, and other support software downloads for ProLiant servers and Options, refer to theNavigation Tips document.SEARCH TIP: For hints on locating similar documents on HPE.com, refer to theSearch Tips document.To search for additional advisories related to Linux, use the following search string:+Advisory +ProLiant -"Software and Drivers" +Linux
Operating Systems Affected:Not Applicable
No external links available for this bug
Click on a version to see all relevant bugs
Hewlett Packard Enterprise Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.