Issue When a restripe job starts its 'mark' phase, the job fails and an event similar to the following appears on the Events page in the OneFS web administration interface and when running the isi events command from the OneFS command-line interface: ID STARTED ENDED SEV LNN MESSAGE. 6.17409 2013-11-11 20:32:01 -- I 15 IDI failure. OneFS has detected a serious problem. Please contact Isilon support for resolution of this problem immediately (l 1:0622:0902::HEAD b 6,23,256780394496:8192, Accessing a gone drive on mark)
Cause Occasionally, when a drive is smart failed, some protection groups that belong on that drive are not written to healthy drives. This leaves some files in a less-protected state.
Solution Contact Isilon Technical Support.