np-f port uplinks are configured in a port channel between UCS FI and a Connectrix MDS 9000 series switch. Symptom 1: The Connectrix MDS switch logs the following errors in the show logging log after the port channel is enabled: mds01-a %PORT-5-IF_DOWN_OLS_RCVD: %$VSAN 1060%$ Interface fc2/1 is down (OLS received) port-channel200 mds01-a %PORT-5-IF_DOWN_OLS_RCVD: %$VSAN 1060%$ Interface fc1/9 is down (OLS received) port-channel200 mds01-a %PORT-5-IF_DOWN_OLS_RCVD: %$VSAN 1060%$ Interface fc2/9 is down (OLS received) port-channel200 mds01-a %PORT-5-IF_DOWN_OLS_RCVD: %$VSAN 1060%$ Interface fc1/1 is down (OLS received) port-channel200 Symptom 2: The UCS FI logs the following errors in the show logging log after the port channel is enabled: fi01-A %PORT-5-IF_DOWN_EPP_FAILURE: %$VSAN 1060%$ Interface fc1/2 is down (Error Disabled - EPP Failure) san-port-channel 200 fi01-A %PORT-5-IF_DOWN_EPP_FAILURE: %$VSAN 1060%$ Interface fc1/3 is down (Error Disabled - EPP Failure) san-port-channel 200 fi01-A %PORT-5-IF_DOWN_EPP_FAILURE: %$VSAN 1060%$ Interface fc1/4 is down (Error Disabled - EPP Failure) san-port-channel 200 fi01-A %PORT-5-IF_DOWN_EPP_FAILURE: %$VSAN 1060%$ Interface fc1/1 is down (Error Disabled - EPP Failure) san-port-channel 200 fi01-A %PORT-5-IF_DOWN_PORT_CHANNEL_MEMBERS_DOWN: %$VSAN 1060%$ Interface san-port-channel 200 is down (No operational members) Symptom 3: The Connectrix MDS interfaces in the port channel enter a link failure state. Symptom 4: The UCS FI interfaces enter a bit error disabled state. The status may also show as InvalidCFG or a similar value. Symptom 5: The global trunking protocol feature is disabled on the Connectrix MDS switch under the command: show trunk protocol show trunk protocol Trunk Protocol is disabled
The trunk protocol is disabled on the Connectrix MDS switch.
Procedure: Enable the trunking protocol. Run the following commands: config trunk protocol enable end copy r s Verify that the trunk protocol is enabled. Run the following command: show trunk protocol Configure the port channels.
Click on a version to see all relevant bugs
Dell Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.