No disks are showing up as available in "Create asm Disk Group" although the hdisk (if MPIO is used) or the hdiskpower (if PowerPath is used) are "available."
To ensure successful database, client, and grid infrastructure installation, IOCP (I/O completion Port) must be set to " Available". By default, iocp is set to "Defined" (can be checked in an emcgrab in "lsdev -C" output) # lsdev | grep iocpiocp0 Defined I/O Completion Ports The above sample output shows that the IOCP status is set to Defined and hence not enabled: No device shows up.
To ensure a successful database, client, and grid infrastructure installation, IOCP must be set to " Available" using this procedure. Log in as root and run the following command: # smitty iocp Select Change/Show Characteristics of I/O Completion Ports. Change configured state at system restart from Defined to Available . Run the lsdev command to confirm the IOCP status is now set to Available : $ lsdev | grep iocp iocp0 Available I/O Completion Ports Restart the system to make the changes permanent. (reboot)