Ndu pre-check error: Verify management network redundancy.. ERROR VPlexcli:/> ndu pre-check Verify management network redundancy.. ERROR VPlexcli:/>ndu pre-check --verbose (***run on Cluster-2) No management connectivity to /engines/engine-1-1/directors/director-1-1-A at IP 128.221.253.35 [ERROR]: No management connectivity to /engines/engine-1-1/directors/director-1-1-B at IP 128.221.253.36 [ERROR]: No management connectivity to /engines/engine-1-2/directors/director-1-2-A at IP 128.221.253.37 [ERROR]: No management connectivity to /engines/engine-1-2/directors/director-1-2-B at IP 128.221.253.38 [ERROR]: No management connectivity to /engines/engine-1-3/directors/director-1-3-A at IP 128.221.253.39 [ERROR]: No management connectivity to /engines/engine-1-3/directors/director-1-3-B at IP 128.221.253.40 [ERROR]: No management connectivity to /engines/engine-1-4/directors/director-1-4-A at IP 128.221.253.41 [ERROR]: No management connectivity to /engines/engine-1-4/directors/director-1-4-B at IP 128.221.253.42 [ERROR]:
On further investigation the following behavior can be seen:Each MMCS (MMCS-A and MMCS-B) could ping all Directors across both VPlex Clusters on the 128.221.252 (MMCS-A) and 128.221.253 (MMCS-B) networks.In this case, MMCS-B on both (Cluster-1 and Cluster-2) is not able to ping the Remote Directors on the 128.221.253 network however the Local Directors are pinging OK from both MMCS-B's on the 128.221.253 network. It was not possible to SSH into MMCS-B on Cluster-2….MMCS-B on Cluster2 was replaced to resolve the issue.
MMCS-B on Cluster2 was replaced to resolve the issue.ndu-pre-checks are now clean and error free.
Click on a version to see all relevant bugs
Dell Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.