Observed Issue The following symptoms have been identified: PSU redundant setting (PSU 1+1 configuration) is correctly configured in the iDRAC Redundancy Policy. PSU redundant behavior is incorrect, and work as Not Redundant mode (PSU 2+0 configuration). Impact scope: iDRAC version 1.30.05.10
iDRAC unexpected behavior issue
Short-term solution There is a workaround can fix the issue. Manually configure a PSU Redundancy cycle: Set PSU Redundancy to Not Redundant first then change to A/B Grid Redundant (1+1 Redundant). Long-term solution iDRAC version released in March block can fix the issue.