No degraded or failed capacity No SDSs decoupled or SDS devices reporting errors. No disconnected MDMs The replication feature is being used. One or more alerts in the UI reporting the following errors: Major - The RCG consistent image is too large to be consumed by the destination in one piece.Minor - Remote Consistency Group RPO Exceeded MDM event logs may report the following: 2024-06-11 15:55:56.592000:0001566:RPL_PD_CAP_UTILIZATION_MINOR WARNING Protection Domain ID <pd_id> Replication journal capacity is at MINOR utilization level 2024-06-11 16:20:12.848000:0001567:RPL_PD_CAP_UTILIZATION_MAJOR ERROR Protection Domain ID <pd_id> Replication journal capacity is at MAJOR utilization level 2024-06-11 17:19:57.272000:0001584:RPL_PD_CAP_UTILIZATION_CRITICAL CRITICAL Protection Domain ID <pd_id> Replication journal capacity is at VERY_HIGH utilization level 2024-06-11 17:52:26.352000:0001585:RPL_PD_CAP_UTILIZATION_CRITICAL CRITICAL Protection Domain ID <pd_id> Replication journal capacity is at CRITICAL utilization level ... 2024-06-11 16:25:14.381000:0001576:RPL_CG_MOVED_TO_SLIM_MODE INFO Replication Consistency Group ID <rcg_id> entered slim mode 2024-06-11 18:27:29.738000:0001586:SDR_CRITICAL_CAP_CHANGE ERROR SDR ID <sdr_id>) handling user data changed discarded old user data and stopped to accumulate new user data due critical capacity Impact Clients are unable to access volumes that are intercepted for replication.
A rare software defect may occur where the MDM and the SDR component disagree on the internal counters related to journal capacity. This discrepancy may cause the MDM to unallocated additional journal capacity when the SDR's capacity is full, potentially leading to IO errors on client/servers using devices backed by PowerFlex.
A rolling restart of all SDR components is required, and the MDM ownership on the source system must be switched to resolve the issue. Restart SDR components: 1) Identify all the SDRs: scli --query_all_sdr 2) Enter maintenance mode on the SDR: scli --enter_sdr_maintenance_mode --sdr_name <name> 3) Validate that the SDR is fully in maintenance mode by running the command in step 1. 4) Restart the SDR component. pkill sdr 5) Repeat this for all SDRs on the source site . Once all SDRs are restarted, switch the MDM ownership: #3.x scli --switch_mdm_ownership --new_master_mdm_name <name> #4.x scli --switch_mdm_ownership --new_primary_mdm_name <name> *If wanted, the ownership can be transferred back to the original MDM server. Validate that the IO errors on the client/servers are no longer are reported. If the client has entered a read-only file system, the client/server may require a reboot. Until the cause can be determined, it will also be recommended that all RCGs on the source system be terminated. If the IO errors continue after applying the above steps, engage PowerFlex Engineering.
Click on a version to see all relevant bugs
Dell Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.