The output of the status.dpn command shows one or more maintenance activities reporting MSG_ERR_DISKFULL : # status.dpn Tue Jan 14 18:26:56 PST 2025 [AVE01] Wed Jan 15 02:26:56 2025 UTC (Initialized Tue Feb 1 05:02:45 2022 UTC) Node IP Address Version State Runlevel Srvr+Root+User Dis Suspend Load UsedMB Errlen %Full Percent Full and Stripe Status by Disk 0.0 192.168.255.1 19.4.0-124 ONLINE fullaccess mhpu+0hpu+0hpu 1 false 0.15 55075 3800263240 64.1% 64%(onl:1778) 64%(onl:1780) 64%(onl:1777) Srvr+Root+User Modes = migrate + hfswriteable + persistwriteable + useraccntwriteableSystem ID: 1643691765@00:01:02:03:04:05All reported states=(ONLINE), runlevels=(fullaccess), modes=(mhpu+0hpu+0hpu) System-Status: ok Access-Status: fullCheckpoint failed with result MSG_ERR_DISKFULL : cp.20250114220752 started Tue Jan 14 14:08:12 2025 ended Tue Jan 14 14:08:12 2025, completed 0 of 5335 stripes Last GC: finished Tue Jan 14 14:02:10 2025 after 00m 22s >> recovered 36.24 KB (MSG_ERR_DISKFULL) Last hfscheck: finished Tue Jan 14 14:06:55 2025 after 04m 18s >> checked 1250 of 1250 stripes (OK)Maintenance windows scheduler capacity profile is active. The maintenance window is currently running. Next backup window start time: Tue Jan 14 21:00:00 2025 PST The Avamar grid has a high utilization: # mccli server show-prop 0,23000,CLI command completed successfully. Attribute Value -------------------------------------------- ---------------------------- State Suspended Active sessions 0 Total capacity 562.4 GB Capacity used 562.3 GB Server utilization 98.9% Bytes protected (client pre-comp size) 560 GB Bytes protected quota (client pre-comp size) Not configured License expiration Never Time since Server initialization 1078 days 21h:32m Last checkpoint 2025-01-14 14:07:52 PST Last validated checkpoint 2025-01-14 14:02:12 PST System Name AVE01 System ID 1643691765@00:01:02:03:04:05 HFSAddr ave01 HFSPort 27000 IP address 192.168.255.1 Number of nodes 1 Nodes Online 1 Nodes Offline 0 Nodes Read-only 0 Nodes Timed-out 0 One or more of the Avamar data partitions has a high utilization: avmaint nodelist | egrep 'nodetag|fs-percent-full' Example output from a single node grid: nodetag="0.0" fs-percent-full="96.9" fs-percent-full="96.9" fs-percent-full="96.9" Example output from a Multinode grid: (The command can help identify the high Operating System (OS) capacity per node) nodetag="0.2" fs-percent-full="96.7" fs-percent-full="96.9" fs-percent-full="96.9" nodetag="0.1" fs-percent-full="96.9" fs-percent-full="96.4" fs-percent-full="96.8" nodetag="0.0" fs-percent-full="96.3" fs-percent-full="96.8" fs-percent-full="96.7"
The likely cause is one of these two reasons: 1. Sudden and large amounts of change in the data backed up: Sudden and large amounts of change in the data backed up by an Avamar client can have a negative impact on the grid. Note: This can include backups accidentally backed up to the Avamar Server (GSAN) instead of an attached Data Domain (DD). If too much data is added or removed, the Operating System (OS) capacity can spike, causing maintenance to fail with MSG_ERR_DISKFULL. Checkpoints track changes on Avamar so that if a rollback is needed, Avamar can be returned to that point in time. When a large amount of data is added or removed, the checkpoint becomes larger and consumes extra space in the OS. 2. The daily change rate is too high: A lot of data change within a single day can cause a sudden spike in the OS capacity. Change means high intake of new data and rapid removal of old data. Change should be introduced to Avamar gradually where possible. The more full a grid is, the higher the impact of a spike in changed data. The capacity.sh script is helpful in tracking the change rate on a grid. For information about how to use the capacity.sh script, see Avamar: How to manage capacity with the capacity.sh script. Example capacity.sh usage:: # capacity.sh DATE AVAMAR NEW #BU DDR NEW #BU SCANNED REMOVED MINS PASS AVAMAR NET CHG RATE ========== ============= ==== ============= ==== ============= ============= ==== ==== ============= ========== 2024-12-04 1770185 mb 367 36590255 mb 4414 427354917 mb -1155011 mb 179 36 615174 mb 8.98% 2024-12-05 1799386 mb 366 35834788 mb 4384 424229450 mb -967906 mb 158 36 831480 mb 8.87% 2024-12-06 1641614 mb 366 36339601 mb 4387 422918309 mb -715952 mb 95 36 925662 mb 8.98% 2024-12-07 1482274 mb 368 36021600 mb 4382 422096834 mb -1369565 mb 182 35 112708 mb 8.89% 2024-12-08 1476971 mb 376 35466632 mb 4379 418749502 mb -882663 mb 120 36 594307 mb 8.82% 2024-12-09 2338688 mb 377 36564862 mb 4408 426949173 mb -521711 mb 102 36 1816976 mb 9.11% 2024-12-10 1830728 mb 482 36776445 mb 4303 423650873 mb -369845 mb 80 36 1460882 mb 9.11% 2024-12-11 10323736 mb 478 33010286 mb 4416 435953105 mb -1016271 mb 159 34 9307465 mb 9.94% 2024-12-12 8773933 mb 473 32431241 mb 4399 442013401 mb -167120 mb 64 35 8606813 mb 9.32% 2024-12-13 8834627 mb 485 31265504 mb 4378 434459112 mb -186507 mb 60 35 8648119 mb 9.23% 2024-12-14 8605313 mb 479 31150950 mb 4391 434117515 mb -32753 mb 41 35 8572559 mb 9.16% 2024-12-15 10727441 mb 478 32164212 mb 4393 435520200 mb -58643 mb 53 36 10668797 mb 9.85% 2024-12-16 10133770 mb 477 31557436 mb 4396 432462001 mb -55780 mb 43 36 10077989 mb 9.64% 2024-12-17 9941271 mb 477 30824614 mb 4419 434292081 mb -68284 mb 53 35 9872986 mb 9.39% 2024-12-18 10147447 mb 416 24608011 mb 3237 319673822 mb -577890 mb 124 35 9569557 mb 10.87% ================================================================================================================ 14 DAY AVG 5988492 mb 431 33373763 mb 4312 422296020 mb -543060 mb 101 35 5445432 mb 9.32% 30 DAY AVG 3622366 mb 403 36648167 mb 4353 427001356 mb -1326697 mb 150 34 2295669 mb 9.43% 60 DAY AVG 3047161 mb 392 34199043 mb 4323 417800256 mb -1489983 mb 159 34 1557178 mb 8.91%
Caution: Before proceeding, ensure that the capacity issue is NOT due to accidental backups to the GSAN . If this is the case, stop referencing this article and create a Swarm with the Avamar SCR team ASAP. 1. Verify that the checkpoint and hfscheck retentions are set to the default values of 2 and 1: # avmaint config --ava | grep "cpmostrecent\|cphfschecked" cpmostrecent="2" cphfschecked="1" If these values are incorrect, run the following command: # avmaint config --ava cpmostrecent=2 cphfschecked=1 Example output if the previous values were 5 and 3: <?xml version="1.0" encoding="UTF-8" standalone="yes"?> <gsanconfig cpmostrecent="5" cphfschecked="3"/> Note: If the checkpoint retentions were not the default, the OS capacity should drop during the next maintenance cycle. Either run maintenance manually, or monitor the grid until the next maintenance cycle has been completed. If the capacity issues remain, Open a Service Request with the Dell Technologies Avamar Support team referencing this knowledge article. 2. Disable async crunching so that the OS capacity does not continue to grow during the troubleshooting process: # avmaint config --ava asynccrunching=false <?xml version="1.0" encoding="UTF-8" standalone="yes"?> <gsanconfig asynccrunching="true"/> 3. Check the status of the OS data partition capacities: # avmaint nodelist | egrep 'nodetag|fs-percent-full' Sample output from a single node: nodetag="0.0" fs-percent-full="96.9" fs-percent-full="96.9" fs-percent-full="96.9" Sample output from a Multinode: nodetag="0.2" fs-percent-full="96.7" fs-percent-full="96.9" fs-percent-full="96.9" nodetag="0.1" fs-percent-full="96.9" fs-percent-full="96.4" fs-percent-full="96.8" nodetag="0.0" fs-percent-full="96.3" fs-percent-full="96.8" fs-percent-full="96.7" 4. If the highest fs-percent full is: Above 98%: Open a Service Request with the Dell Technologies Avamar Support team referencing this knowledge article. Above 96%, but below 98%: If the checkpoint retentions were already set to the default, Open a Service Request with the Dell Technologies Avamar Support team referencing this knowledge article. If the checkpoint retentions were not the default, the OS capacity should drop during the next maintenance cycle. Either run maintenance manually, or monitor the grid until the next maintenance cycle has been completed. If the capacity issues remain, Open a Service Request with the Dell Technologies Avamar Support team referencing this knowledge article Above 89%, but below 96%: Checkpoints will complete successfully, and the OS capacity should drop during the next maintenance cycle. Either run maintenance manually, or monitor the grid until the next maintenance cycle has been completed. If the capacity issues remain, Open a Service Request with the Dell Technologies Avamar Support team referencing this knowledge article
Click on a version to see all relevant bugs