This is a monitoring issue and does NOT affect backups from Avamar to Data Domain (DD). If backups are failing when Data Domain monitoring status is not reporting OK, stop following this article. The Avamar monitoring status for Data Domain changes to Yellow or Red from Green in the Avamar Administrator UI One or more of the following errors may also appear in the UI: Error: Unable to get SNMP file system status Error: Unable to get file system information Error: Unable to get disk status Error: Unable to retrieve ssh keys
The necessary ports for Simple Network Management Protocol (SNMP) are not provisioned in the Avamar or Data Domain environment. -- Or -- A firewall, or firewalls between the Avamar and Data Domain are filtering (blocking) one or more of the SNMP packets.
Ensure that port 163 is open. Ensure that trap port 161 (default), or 162 is open. Note: As SNMP uses UDP ports, using telnet or curl is not a viable option to check whether these ports are open. If the issue remains unresolved, see the resolution path for SNMP issues: Avamar: Troubleshooting Data Domain Integration Errors in the Avamar Administrator UI (Resolution Path)