NetWorker backups of DB2 databases can fail with the following errors: C:\Program Files\EMC NetWorker\nsr\bin>db2 update db cfg for DBNAME using logarchmeth1 VENDOR:"C:\Program Files\EMC NetWorker\nsr\bin\libnsrdb2.dll" logarchopt1 "C:\Program Files\EMC NetWorker\nsr\apps\config\nmda_db2_tlogs.cfg" SQL0104N An unexpected token "Files\EMC" was found following "<identifier>" Expected tokens may include: "ACT_SORTMEM_LIMIT" SQLSTATE=42601
This failure is the result of a mistake in the syntax of the backup command.
The backup command must use the Windows Short Path convention. For example: Full Path: C:\Program Files\EMC NetWorker Short Path: C:\PROGR~1\EMCNET~1 The same command in the symptoms section that failed would instead include the short path: db2 update db cfg for DBNAME using logarchmeth1 VENDOR:C:\PROGRA~1\EMCNET~1\nsr\bin\libnsrdb2.dll logarchopt1 C:\PROGRA~1\EMCNET~1\nsr\apps\config\nmda_db2_tlogs.cfg