The backup job error shows: ABV0025: VM Direct engine is unable to configure protection for the virtual machine 'MY-VM-NAME' on vCenter 'MY-VCENTER-NAME'.More Details: Unable to ENABLE LWD on MY-VM-NAME - SPIF filters change failure: The virtual disk requires a feature not supported by this program The /var/log/brs/vmdm/vmdm.log shows: YYYY-MM-DD HH:MM:SS INFO [] [vpe-thread-1732] [00000000-0000-4000-a000-000000000000][][][TRACE_ID:8be5dc10f65f9aea;JOB_ID:8e3ff4714ff1285b][] [c.e.b.v.v.u.SdmEnableProtectUtil.waitForVsanTask(496)] - Task Task-task-2821445 state=ERROR name=null YYYY-MM-DD HH:MM:SS WARN [] [vpe-thread-1732] [00000000-0000-4000-a000-000000000000][][][TRACE_ID:8be5dc10f65f9aea;JOB_ID:8e3ff4714ff1285b][] [c.e.b.v.v.u.SdmEnableProtectUtil.configureProtect(465)] - Unable to ENABLE LWD on MY-VM-NAME YYYY-MM-DD HH:MM:SS WARN [] [vpe-thread-1732] [00000000-0000-4000-a000-000000000000][][][TRACE_ID:8be5dc10f65f9aea;JOB_ID:8e3ff4714ff1285b][] [c.e.b.v.v.u.SdmEnableProtectUtil.configureProtect(478)] - DpSetProtection error message: SPIF filters change failure: The virtual disk requires a feature not supported by this program. YYYY-MM-DD HH:MM:SS WARN [] [vpe-thread-1732] [00000000-0000-4000-a000-000000000000][][][TRACE_ID:8be5dc10f65f9aea;JOB_ID:8e3ff4714ff1285b][] [c.e.b.v.v.a.VPEConfigureOp.logErrorStack(64)] - Unable to configure MY-VM-NAME com.emc.brs.vmdm.error.ComponentException: Unable to ENABLE LWD on MY-VM-NAME - SPIF filters change failure: The virtual disk requires a feature not supported by this program. at com.emc.brs.vmdm.vpe.util.SdmEnableProtectUtil.configureProtect(SdmEnableProtectUtil.java:484) at com.emc.brs.vmdm.vpe.util.SdmEnableProtectUtil.configureProtection(SdmEnableProtectUtil.java:253) at com.emc.brs.vmdm.vpe.util.SdmEnableProtectUtil.configureProtection(SdmEnableProtectUtil.java:265 …
The VM contains a virtual hard disk that is using SCSI bus sharing. The PowerProtect Data Manager VM Protection solution does not support disks with SCSI bus sharing.
The virtual machine configuration must be updated to not include a hard disk with SCSI bus sharing. An alternative is to use the PowerProtect File System Agent can be used to protect the Asset.
Click on a version to see all relevant bugs
Dell Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.