The Data Domain system health check feature introduced in DDOS 8.4 may report a cloud endpoint port connectivity error even if there are no such issues. sysadmin@dd01# system health check Warning : This command may take few minutes to complete. Please wait... DD Health Check Completed!!! *********===============================================================================================================********** System Information: Model number: DD VE Serial number: xxxxxxxxxxxx System software-id: Not available Instance software-id: Not available Version : Data Domain OS 8.4.0.0-1170724 Hostname : : dd01.example.com Instance Software Identifier (iSWID) :NA System Software Identifier (eSWID) :NA File System Status : The filesystem is enabled and running. Memory Information : Memory Usage Summary Total memory: 60296 MiB Available memory: 17483 MiB Total swap: 4093 MiB Free swap: 4093 MiB 21:00:44 up 3 days, 23:43, 2 users, load average: 10.46, 11.17, 11.41 Filesystem has been up 0 days, 02:29. Current Alert : No active alerts. *********===============================================================================================================********** SOFTWARE Health Check Summary: +--------------------+---------+ | Component | Status | +--------------------+---------+ | SMS Health | PASS | | File System | PASS | | Cloud Unit | ERROR | | Capacity | WARNING | | Garbage Collection | PASS | | Performance | INFO | | Certificates | PASS | | User Interface | PASS | | DNS | PASS | | User | PASS | | Replication | PASS | | Logical Volume | PASS | +--------------------+---------+ *********===============================================================================================================********** SOFTWARE Action/Attention Needed Check Table +-------------+---------------------+---------+-------------------------------------+-------------------------------------+ | Component | Check | Status | Message | Remedy | +-------------+---------------------+---------+-------------------------------------+-------------------------------------+ | Cloud Unit | Cloud Endpoint port | ERROR | Command execution failed with error | | | | connectivity check | | telnet: connect to address | | | | 8080 | | 0.0.31.144: Connection timed out | | | | | | , skipping check | | +-------------+---------------------+---------+-------------------------------------+-------------------------------------+
Data Domain Engineering has identified a code defect where the health check feature uses the wrong port number to check cloud provider connectivity.
Manually verify the cloud provider and check if the cloud unit is in a disconnected state. If it is connected without issue, it is safe to ignore this error. Example: System without cloud connectivity issues: sysadmin@dd01# cloud profile show Profile name: ECS_Profile1 Provider: ecs Endpoint: https://haproxy.example.com:443 Version: 3.8.1.4.140200.8103892f11b Proxy host: Proxy port: 0 Proxy username: Profile name: ECS_Profile2 Provider: ecs Endpoint: https://haproxy.example.com:443 Version: 3.8.1.4.140200.8103892f11b Proxy host: Proxy port: 0 Proxy username: sysadmin@dd01# cloud unit list Name Profile Status Bucket Reason --------- ------------ ------ ------------------------------------ ------------------------------- ECS_Unit1 ECS_Profile1 Active 2bd43735a749403b-bc814429bd6eca92-d0 Cloud unit connected and ready. ECS_Unit2 ECS_Profile2 Active 8dfd3d92f7246847-63e08e68f7c293c0-d0 Cloud unit connected and ready. --------- ------------ ------ ------------------------------------ ------------------------------- This issue is fixed in DDOS 8.5 and later releases.
Click on a version to see all relevant bugs
Dell Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.