NetWorker clone operation is reading from the first backup volume instead of the selected clone volume.
Code inefficiency.
This issue is addressed in the following NetWorker versions: 19.12.0.3 19.13.0.2 Workaround: Use short Save Set ID (SSID) in the clone list instead of long SSID. The following output demonstrates the difference between a short SSID and a long SSID: [root@nsr ~]# mminfo -avot -t today -r "ssid,ssid(55)" ssid ssid 2409577825 c12c086d-00000006-8f9f3d61-689f3d61-00725000-ade5be56 2392800613 9d8079bb-00000006-8e9f3d65-689f3d65-00735000-ade5be56 2376023404 c58b77b9-00000006-8d9f3d6c-689f3d6c-00745000-ade5be56 2359255533 a63cf140-00000006-8c9f61ed-689f61ed-00755000-ade5be56 2342478317 2de7028d-00000006-8b9f61ed-689f61ed-00765000-ade5be56 2325701101 6195ef1a-00000006-8a9f61ed-689f61ed-00775000-ade5be56 2308923885 0bc86a02-00000006-899f61ed-689f61ed-00785000-ade5be56 2292146669 47ba8795-00000006-889f61ed-689f61ed-00795000-ade5be56 2275369453 72f8feb0-00000006-879f61ed-689f61ed-007a5000-ade5be56 2258592237 3e8a1327-00000006-869f61ed-689f61ed-007b5000-ade5be56 2241815021 805b4b01-00000006-859f61ed-689f61ed-007c5000-ade5be56 The first column shows the short SSID. The second column shows the long SSID.