To understand Non-Recoverable disk errors. The customer experiences performance problems and Data Unavailability with a drive that is in an unknown state.
All 0x4 sense key errors indicate that the disk drive detected an unrecoverable hardware failure while performing the command or during a self-test. It experienced an abnormal rotation of the motor spindle. Error Codes: KCQ(4:01:0) # Hardware Error - no index or sector KCQ(4:02:0) # Hardware Error - no seek complete KCQ(4:03:0) # Hardware Error - write fault KCQ(4:09:0) # Hardware Error - track following error KCQ(4:11:0) # Hardware Error - unrecovered read error in reserved area KCQ(4:15:1) # Hardware Error - Mechanical positioning error KCQ(4:16:0) # Hardware Error - Data Sync Mark error in reserved area KCQ(4:19:0) # Hardware Error - defect list error KCQ(4:19:2) # Hardware Error - defect list error in Primary List KCQ(4:19:3) # Hardware Error - defect list error in Grown List KCQ(4:31:0) # Hardware Error - reassign failed KCQ(4:32:0) # Hardware Error - no defect spare available KCQ(4:35:1) # Hardware Error - unsupported enclosure function KCQ(4:35:2) # Hardware Error - enclosure services unavailable KCQ(4:35:3) # Hardware Error - enclosure services transfer failure KCQ(4:35:4) # Hardware Error - enclosure services refused KCQ(4:35:5) # Hardware Error - enclosure services checksum error KCQ(4:3E:3) # Hardware Error - self-test failed KCQ(4:3E:4) # Hardware Error - unable to update self-test KCQ(4:44:0) # Hardware Error - internal target failure
Dispatch a replacement drive on the first occurrence of this error.
Click on a version to see all relevant bugs
Dell Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.