Below are the excerpts from the logs to support the above defect: 2024/06/19-02:47:46:492523 (GMT), [HIL-5011], 165641/0, SLOT 2 | CHASSIS, INFO, ED_DCX7_8B, Kick Start Fan 3, Last 4 speeds below thresh: 3382, 0, 0, 0) lr=1, hil_allegiance_, line: 1905, comp:emd, ltime:2024/06/19-02:47:46:492327 2024/06/19-02:47:50:902888 (GMT), [HIL-5011], 165642/0, SLOT 2 | CHASSIS, INFO, ED_DCX7_8B, Kick Start Fan 3, Last 4 speeds below thresh: 3386, 0, 0, 0) lr=1, hil_allegiance_, line: 1905, comp:emd, ltime:2024/06/19-02:47:50:902773 2024/06/19-02:47:55:339725 (GMT), [HIL-5011], 165643/0, SLOT 2 | CHASSIS, INFO, ED_DCX7_8B, Kick Start Fan 3, Last 4 speeds below thresh: 3436, 0, 0, 0) lr=1, hil_allegiance_, line: 1905, comp:emd, ltime:2024/06/19-02:47:55:339609
This is due defects FOS-850500 and FOS-856476. FOS-850500 Issue: User observes Fan kick starts and stays at a high speed. Closed in Release: FOS9.1.1d (Implemented), FOS9.2.0b (Implemented), FOS9.2.1a (Implemented) Defect Condition: After an i2c reset, the Fan controller is not ready but the software is reading fan speed with invalid data, and falsely believing the fan has stopped. First Affected Release: FOS9.1.1b FOS-856476 Issue: CLI fanshow shows Fan absent when re-inserted. Closed in Release: FOS9.2.0b (Implemented), FOS9.2.1a (Implemented) Defect Condition: Remove Fan out of chassis, then inserted back on X6 and X7 platforms. First Affected Release: FOS9.1.1d
The issue is resolved on FOS 9.2.0b and FOS 9.2.1a.
Click on a version to see all relevant bugs
Dell Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.