Loading...
Loading...
Environment: Fabric OS 9.1.1c Issue: The outputs show errors when running an inline command from a UNIX or Linux server. The command stops responding when probing a different logical Switch FID on the same chassis. Example: [hosttest@VM1234 ~]$ [hosttest@VM1234 ~]$ ssh aa.bb.cc.dd fosexec --fid 44 -cmd 'firmwareshow' hosttest@aa.bb.cc.dd's password: /bin/stty: 'standard input': Inappropriate ioctl for device /bin/stty: 'standard input': Inappropriate ioctl for device /etc/ssh_inline_profile: line 25: FUNCNEST: readonly variable Appl Primary/Secondary Versions ------------------------------------------ FOS v9.1.1c v9.1.1c ---------------------------------------------------"firmwareshow" on FID 44:[hosttest@VM3198 ~]$
This issue was found during internal testing. A change in the error was found when upgrade to FOS 9.2.0a was done. Error: [hosttest@VM3198 ~]$ [hosttest@VM3198 ~]$ ssh aa.bb.cc.dd fosexec --fid 44 -cmd 'firmwareshow' hosttest@10.60.23.25's password: /bin/stty: 'standard input': Inappropriate ioctl for device /bin/stty: 'standard input': Inappropriate ioctl for device Appl Primary/Secondary Versions ------------------------------------------ FOS v9.2.0a v9.2.0a ---------------------------------------------------"firmwareshow" on FID 44:[hosttest@VM3198 ~]$
Resolution: Upgrade to Fabric OS 9.2.0b or later. Workaround: Run the commands directly on the switch.