The PowerProtect Data Manager Appliance is used to protect the vSphere environment with the VM Direct Engine solution. The VM Direct Engine deployment fails with an error validation indicating the IP address is already being used on the network. Error Not able to deploy VM Direct Engines - Unable to configure the network 'VM Direct Protection Engine '192.168.1.x' because an IP conflict was detected for '192.168.1.x'. The vmdm.log shows: ... YYYY-MM-DD HH:MM:SS INFO [https-jsse-nio-0.0.0.0-8447-exec-9] [][][][TRACE_ID:8610c22e530b04b5][] [ProxyVlanNetworkHelper.validateIpAddresses(1464)] - Task completed: ipAddr=192.168.1.x, netInterface=eth0, conflict=true status=1, out=ARPING 192.168.1.x from 0.0.0.0 eth0 Unicast reply from 192.168.1.x [00:50:56:88:09:D5] 0.906ms Sent 1 probes (1 broadcast(s)) Received 1 response(s) , err= YYYY-MM-DD HH:MM:SS ERROR [https-jsse-nio-0.0.0.0-8447-exec-9] [][][][TRACE_ID:8610c22e530b04b5][] [ProxyVlanNetworkHelper.validateIpAddresses(1477)] - conflict detected for IP addresses [192.168.1.x] YYYY-MM-DD HH:MM:SS WARN [https-jsse-nio-0.0.0.0-8447-exec-9] [][][][TRACE_ID:8610c22e530b04b5][] [c.e.b.v.a.ActivityBuilder.complete(603)] - Setting activity start time to now. YYYY-MM-DD HH:MM:SS INFO [https-jsse-nio-0.0.0.0-8447-exec-9] [][][][TRACE_ID:8610c22e530b04b5][] [c.e.b.v.a.ActivityBuilder.complete(623)] - Completed activity id=4241ddf4-da8e-497f-be32-8e993993c47c, status=FAILED YYYY-MM-DD HH:MM:SS ERROR [https-jsse-nio-0.0.0.0-8447-exec-9] [][][][TRACE_ID:8610c22e530b04b5][] [c.e.b.v.e.VmdmRestErrorHandler.logError(294)] - Exception Trace - com.emc.brs.vmdm.error.Conflict: Unable to configure the network 'VM Direct Protection Engine '192.168.1.x'' because an IP conflict was detected for '192.168.1.x'. at com.emc.brs.vmdm.vpe.service.helpers.ProxyVlanNetworkHelper.validateIpAddresses(ProxyVlanNetworkHelper.java:1478) ...
The VM Direct Engine deployment does not allow a duplicate IP address to be used in the environment. The IP address was not responding to Internet Control Message Protocol (ICMP) pings from the Administrator's desktop but was responding to from the PowerProtect Appliance.
Resolve the IP conflicts in the environment or use a different IP address that is not being used in the environment.
Click on a version to see all relevant bugs
Dell Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.