Loading...
Loading...
ePOST errors are seen during the boot process pointing to IMPI and BMC issue. 2023-03-10T10:02:52.724067-05:00 isilon-1 port08 2023-Mar-10 09:02:52.701 RXDATA: ************************************************************ 2023-03-10T10:02:52.724968-05:00 isilon-1 port08 2023-Mar-10 09:02:52.702 RXDATA: * Extended POST Messages 2023-03-10T10:02:52.733503-05:00 isilon-1 port08 2023-Mar-10 09:02:52.710 RXDATA: ************************************************************ 2023-03-10T10:02:52.735390-05:00 isilon-1 port08 2023-Mar-10 09:02:52.712 RXDATA: WARNING:Failed to set fault/status code value:0x01000000 (offset:0x02A8) 2023-03-10T10:02:52.744810-05:00 isilon-1 port08 2023-Mar-10 09:02:52.722 RXDATA: INFORMATION:POST Start 2023-03-10T10:02:52.745778-05:00 isilon-1 port08 2023-Mar-10 09:02:52.723 RXDATA: WARNING:INIT: IPMI Error Reading Chassis Resume PROM (0x03E0) 2023-03-10T10:02:52.746700-05:00 isilon-1 port08 2023-Mar-10 09:02:52.724 RXDATA: WARNING:INIT: IPMI Error Reading SP Resume PROM (0x03E0) 2023-03-10T10:02:52.756213-05:00 isilon-1 port08 2023-Mar-10 09:02:52.733 RXDATA: WARNING:Failed to read Boot Options structure from Virtual EEPROM (0x03E0) 2023-03-10T10:02:52.767540-05:00 isilon-1 port08 2023-Mar-10 09:02:52.744 RXDATA: WARNING:FRU capability Register in SP resume is not set correctly, VRD components are not recognized 2023-03-10T10:02:52.778927-05:00 isilon-1 port08 2023-Mar-10 09:02:52.756 RXDATA: WARNING:Error reading SLIC status sensor or sensor scanning could be disabled for HBA0 card (0x03E0) 2023-03-10T10:02:52.779879-05:00 isilon-1 port08 2023-Mar-10 09:02:52.757 RXDATA: WARNING:Error reading SLIC status sensor or sensor scanning could be disabled for HBA1 card (0x03E0) 2023-03-10T10:02:52.790272-05:00 isilon-1 port08 2023-Mar-10 09:02:52.767 RXDATA: WARNING:Error reading SLIC status sensor or sensor scanning could be disabled for Disk Interface Card (0x03E0) 2023-03-10T10:02:52.801880-05:00 isilon-1 port08 2023-Mar-10 09:02:52.779 RXDATA: WARNING:Unable to read VEEPROM Shared Data Region (0x03E0) 2023-03-10T10:02:52.802975-05:00 isilon-1 port08 2023-Mar-10 09:02:52.780 RXDATA: WARNING:Failed to read Boot Options structure from Virtual EEPROM (0x03E0)2023-03-10T10:02:53.234050-05:00 isilon-1 port08 2023-Mar-10 09:02:53.211 RXDATA: .... Storage System Failure - Contact your Service Representative ... 2023-03-10T10:02:53.246489-05:00 isilon-1 port08 2023-Mar-10 09:02:53.223 RXDATA: WARNING: Failed to set fault/status code value:0x0100001C (offset:0x02A8) 2023-03-10T10:02:53.247503-05:00 isilon-1 port08 2023-Mar-10 09:02:53.224 RXDATA: ErrorCode: 0x00000174 2023-03-10T10:02:53.247995-05:00 isilon-1 port08 2023-Mar-10 09:02:53.225 RXDATA: ErrorDesc: 2023-03-10T10:02:53.248534-05:00 isilon-1 port08 2023-Mar-10 09:02:53.225 RXDATA: FRU: Enclosure | Motherboard 2023-03-10T10:02:53.249004-05:00 isilon-1 port08 2023-Mar-10 09:02:53.226 RXDATA: Device: Enclosure Monitor 2023-03-10T10:02:53.259064-05:00 isilon-1 port08 2023-Mar-10 09:02:53.236 RXDATA: Description: A/B slot indicator Error! 2023-03-10T10:02:53.259567-05:00 isilon-1 port08 2023-Mar-10 09:02:53.237 RXDATA: Rev: 10.34 2023-03-10T10:02:53.260070-05:00 isilon-1 port08 2023-Mar-10 09:02:53.237 RXDATA: SPA: FALSE 2023-03-10T10:02:53.260567-05:00 isilon-1 port08 2023-Mar-10 09:02:53.238 RXDATA: SPB: FALSE 2023-03-10T10:02:53.261102-05:00 isilon-1 port08 2023-Mar-10 09:02:53.238 RXDATA: Survey* 2023-03-10T10:02:53.261614-05:00 isilon-1 port08 2023-Mar-10 09:02:53.239 RXDATA: P/N: 2023-03-10T10:02:53.262120-05:00 isilon-1 port08 2023-Mar-10 09:02:53.239 RXDATA: S/N: 2023-03-10T10:02:53.262629-05:00 isilon-1 port08 2023-Mar-10 09:02:53.240 RXDATA: EndError: 2023-03-10T10:02:53.263133-05:00 isilon-1 port08 2023-Mar-10 09:02:53.240 RXDATA: ErrorTime: 03/10/2023 15:02:22 2023-03-10T10:02:53.269167-05:00 isilon-1 port08 2023-Mar-10 09:02:53.246 RXDATA: ErrorCode: 0x000003E0 2023-03-10T10:02:53.269674-05:00 isilon-1 port08 2023-Mar-10 09:02:53.247 RXDATA: ErrorDesc: 2023-03-10T10:02:53.270192-05:00 isilon-1 port08 2023-Mar-10 09:02:53.247 RXDATA: FRU: Enclosure | Motherboard 2023-03-10T10:02:53.270677-05:00 isilon-1 port08 2023-Mar-10 09:02:53.248 RXDATA: Device: BMC 2023-03-10T10:02:53.281590-05:00 isilon-1 port08 2023-Mar-10 09:02:53.258 RXDATA: Description: IPMI Transport Protocol Not Found Error! 2023-03-10T10:02:53.282096-05:00 isilon-1 port08 2023-Mar-10 09:02:53.259 RXDATA: Rev: 10.34 2023-03-10T10:02:53.282600-05:00 isilon-1 port08 2023-Mar-10 09:02:53.260 RXDATA: Send_IPMI_CMD() 2023-03-10T10:02:53.283112-05:00 isilon-1 port08 2023-Mar-10 09:02:53.260 RXDATA: Failed to get BMC self test results 2023-03-10T10:02:53.283612-05:00 isilon-1 port08 2023-Mar-10 09:02:53.261 RXDATA: Self Test Results* 2023-03-10T10:02:53.284112-05:00 isilon-1 port08 2023-Mar-10 09:02:53.261 RXDATA: P/N: 2023-03-10T10:02:53.284616-05:00 isilon-1 port08 2023-Mar-10 09:02:53.262 RXDATA: S/N: 2023-03-10T10:02:53.285123-05:00 isilon-1 port08 2023-Mar-10 09:02:53.262 RXDATA: EndError: After the above errors, the node will attempt to boot and fail with the following message - Failed to copy PSI config files: Chassis is missing a PSI receipt. Installation config method is PSF: Pulling PSI config files from backup Secondary backup method None is unknown Unable to pull files from None backup Installation config method is PSF: Unable to pull secondary backup files Installation config method is PSF: Copying PSI config files PSF file path /mfg/psi/psf.json does not exist in primary backupFailed to copy PSI config files: Chassis is missing a PSI receipt. A receipt must be provided before the boot will be allowed to continue. To prevent a DL situation, contact Dell EMC Customer Support immediately: United States: 1 800 782 4362 (1 800 SVC 4EMC) Canada: 1 800 543 4782 (1 800 543 4SVC) Worldwide Country Code: 1 508 497 7901Command Options: 1) Enter recovery shell 2) Continue booting 3) Reboot
BMC unresponsive during boot
Will need to power drain the node and then retry-last-action for the firmware upgrade. Please perform the power drain using the documented process from the below article: https://www.dell.com/support/kbdoc/en-us/000020498/how-to-power-cycle-an-isilon-node Once the node is up you will need to retry-last-action to continue the upgrade # isi upgrade retry-last-action --nodes=all
Click on a version to see all relevant bugs
Dell Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.