In the NetWorker configuration, it is possible to add two different DDBoost devices using different users who are created on the DDR as you can see on the following listing: sysadmin@ddve03# user show list User list from node "localhost". Name Uid Role Last Login From Last Login Time Status Disable Date ----------- ---- -------- --------------- ------------------------ ------- ------------ sysadmin 100 admin 10.1.199.1 Thu Nov 10 10:59:44 2022 enabled never secadmin 1000 security <unknown> never enabled never boostuser01 601 none <unknown> never enabled never boostuser02 602 none <unknown> never enabled never ----------- ---- -------- --------------- ------------------------ ------- ------------ sysadmin@ddve03# ddboost user show DD Boost user Using Token Access ------------- ------------------ boostuser01 - boostuser02 - ------------- ------------------ sysadmin@ddve03# mtree list Name Pre-Comp (GiB) Status -------------------- -------------- ----------- /data/col1/backup 0.0 RW /data/col1/SU01 0.0 RW /data/col1/SU02 0.0 RW -------------------- -------------- ----------- sysadmin@ddve03# ddboost storage-unit show Name Pre-Comp (GiB) Status User Report Physical Size (MiB) --------- -------------- ------ ----------- --------------- SU01 0.0 RW boostuser01 - SU02 0.0 RW boostuser02 - --------- -------------- ------ ----------- --------------- During the clone action in the /nsr/logs/daemon.raw (or C:\Program Files\EMC NetWorker\nsr\logs for Windows installation) log got the following information: 123316 11/10/22 11:15:13 nsrworkflow NSR notice Starting action 'Fs/Filesystem/clone' with command: 'nsrclone -a "*policy name=Fs" -a "*policy workflow name=Filesystem" -a "*policy action name=clone" -s networker -b ClonePool -J networker -o -F -S'. 123321 11/10/22 11:15:13 nsrworkflow NSR notice Action 'Fs/Filesystem/clone's log is in '/nsr/logs/policy/Fs/Filesystem/clone_384243.raw'. 38758 11/10/22 11:15:13 nsrd NSR info policy notice: action backup succeeded 71193 11/10/22 11:15:13 nsrd NSR info Protection Policy Notice: Starting action 'clone' for workflow 'Fs/Filesystem' 70920 11/10/22 11:15:19 nsrd NSR info Enhanced cloning:root browsing 70896 11/10/22 11:15:22 nsrd NSR info networker:cloning session saving to pool 'ClonePool' (ClonePool.001) 71193 11/10/22 11:15:22 nsrd NSR info Media Info: clone save set /tmp (ssid=3379351339) for client networker.lab.local was aborted and removed from volume ClonePool.001 70913 11/10/22 11:15:22 nsrd NSR info cloning session:/tmp (11/10/22) done reading 71659 11/10/22 11:15:22 nsrd NSR info networker:cloning session done saving to pool 'ClonePool' (ClonePool.001) 70919 11/10/22 11:15:22 nsrd NSR info Enhanced cloning:root done browsing 71193 11/10/22 11:15:24 nsrd NSR info Error Alert: Clone operation failed with error: 'NSRCLONE failed for one or more savesets.'. 123325 11/10/22 11:15:24 nsrworkflow NSR notice Action 'Fs/Filesystem/clone' failed. 38758 11/10/22 11:15:24 nsrd NSR info policy notice: action clone failed 133555 11/10/22 11:15:24 nsrworkflow NSR notice Workflow 'Fs/Filesystem' failed. 38758 11/10/22 11:15:24 nsrd NSR info policy notice: workflow Filesystem failed 89017 11/10/22 11:15:24 nsrd NSR notice Scheduled resource list: NSR Protection Policy Fs exited with return code 1. 71193 11/10/22 11:15:40 nsrd NSR info Write completion Notice: Writing to volume BackupPool.001 completed 71193 11/10/22 11:16:00 nsrd NSR info Write completion Notice: Writing to volume ClonePool.001 completed
During the cloning process, the Fast Copy mechanism on the DDOS layer does not have the possibility to change the UID/GID of copying files.
Use the same user to connect the Boost Devices from the same DDR.1. Log in to the Data Domain device over SSH using the sysadmin account.2. Change the storage-unit (SU) owner using the following command: ddboost storage-unit modify SU02 user username sysadmin@ddve03# ddboost storage-unit modify SU02 user boostuser01 The 'ddboost modify' command should not be used to modify the 'user' of a BOOSTFS storage-unit. Are you sure? (yes|no) [no]: yes ok, proceeding. Storage-unit "SU02" modified for user "boostuser01". 3. You can confirm that the setting was changed with: ddboost storage-unit show sysadmin@ddve03# ddboost storage-unit show Name Pre-Comp (GiB) Status User Report Physical Size (MiB) SU01 0.0 RW boostuser01 - SU02 0.0 RW boostuser01 - --------- -------------- ------ ----------- --------------- 4. Log in to the NetWorker Management Console and update the device under Devices->Devices. The boost user details can be changed in the Configuration tab of the device properties. 5. Change the user and password to the one set with the ddboost storage-unit modify command run earlier on the Data Domain. 6. Unmount and remount the device to confirm it mounts successfully using the new credentials.
Click on a version to see all relevant bugs
Dell Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.