The PowerProtect FLR session log shows: YYYY-MM-DD HH:MM:SS INFO: [FLR_MOUNT] Unmounting after mount failure: Unable to create datastore 'EMC-vProxy-my-ppmd-proxy.mydomin.com-1657644843' using 'DD_IP_ADDRESS:/data/col1/Daily_Backups_-anada7ppdm1-8290e/vProxy-my-ppmd-proxy.mydomin.com-f245fd45-766b-4000-a539-4a9e3c69d778': ServerFaultCode: An error occurred during host configuration. NFS mount DD_IP_ADDRESS:/data/col1/Daily_Backups_ppdm/vProxy-my-ppmd-proxy.mydomin.com-f245fd45-766b-4000-a539-4a9e3c69d778 failed: Unable to connect to NFS server.
The ESXi hosting the target VM requires TCP connectivity to the Data Domain to mount the Network File System (NFS) datastore.
The environment requires ESXi to Data Domain TCP connectivity over ports 111, 2049, and 2052.