This issue occurs after a long period of supervisor uptime. It will become apparent if a standby supervisor is present and it is reset (ISSU, ISSD, supervisor switchover or standby reset) since it will never come online. show system internal flash indicates that the /nxos/tmp is 100% - `show system internal flash` Mount-on 1K-blocks Used Available Use% Filesystem / 204800 47756 157044 24 /dev/root /proc 0 0 0 0 proc /isan 512000 231592 280408 46 none /var 51200 492 50708 1 none /etc 5120 936 4184 19 none /nxos/tmp 20480 20480 0 100 none /var/log 51200 6212 44988 13 none /var/home 5120 48 5072 1 none
The space is consumed by a file called fm_debug.log.vdc_1*. This can be identified as follows: switch# show system internal dir /nxos/tmp | include fm_debug fm_debug.log.vdc_1.2698 20922368 The following type of syslog messages may be logged: %SYSMGR-2-TMP_DIR_FULL: System temporary directory usage is unexpectedly high at 97%. This is Cisco bug CSCtr15670
Upgrade past nx-os code 5.28d
Click on a version to see all relevant bugs
Dell Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.