Loading...
Loading...
In some cases, the input/output packets/bytes counter are excessively high in the output of the show interface command. This issue occurs when show interfaces is executed more than 24 hours after the device was started, or more than 24 hours after show interfaces was last executed. GigabitEthernet0/0/1 is up, line protocol is up 5 minute output rate 0 bits/sec, 0 packets/sec 4294977454 packets input, 18446744069418626866 bytes, 0 no buffer Received 4294967297 broadcasts (0 IP multicasts) 0 runts, 0 giants, 0 throttles 0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored 0 watchdog, 10157 multicast, 0 pause input 4294978071 packets output, 18446744069418771827 bytes, 0 underruns Output 4294967934 broadcasts (0 IP multicasts) 0 output errors, 0 collisions, 1 interface resets 0 unknown protocol drops 0 babbles, 0 late collision, 0 deferred 0 lost carrier, 0 no carrier, 0 pause output 0 output buffer failures, 0 output buffers swapped out
- First seen on C8130-G2. - Occurs on Gi0/0/0 and Gi0/0/1. - The exact time required for the issue to occur is unclear; however, the issue did not reproduce when show interfaces was executed repeatedly at 10-second intervals.
When the issue happens, "clear counter gi0/0/x" will reset the counter, to perform normal counting.
Cisco Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.