Loading...
Loading...
On C93180YC-FX3, configuring "system memory-threshold" command will not be visible in "show run" or show run all"
on C93180YC-FX3
N/A
HostA(config)# show running-config all | include i memory-thresholds HostA(config)# system memory-thresholds minor 96 severe 97 critical 98 HostA(config)# show run | i i minor HostA(config)# show run all | in minor HostA(config)# HostA(config)# ++ Using "show system memory-thresholds", changes are reflected: but not in any 'show run' command: HostA(config)# show system memory-thresholds System Memory thresholds: Critical:98 Severe:97 Minor:96 HostA(config)# *PSIRT Evaluation:* The Cisco PSIRT has evaluated this issue and determined it does not meet the criteria for PSIRT ownership or involvement. This issue will be addressed via normal resolution channels. If you believe that there is new information that would cause a change in the severity of this issue, please contact psirt@cisco.com for another evaluation. Additional information on Cisco's security vulnerability policy can be found at the following URL: http://www.cisco.com/en/US/products/products_security_vulnerability_policy.html
Cisco Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.