* Does not see hit counts on the ACP rules when security zones are added. * The 'zones.conf' file is found to be empty on FTD, which can be located at the path '/ngfw/var/sf/fwcfg/' root@FTD:/# cd /ngfw/var/sf/fwcfg/ root@FTD:/ngfw/var/sf/fwcfg# cat zones.conf zones { } * Furthermore, rule conditions are empty in 'ngfw.rules'. An example includes Rule ID 268435478 268435478 allow any x.x.x.x 23 any any x.x.x.x 26 any any any 268435478 allow any x.x.x.x 24 any any x.x.x.x 25 any any any # End rule 268435478 # End rule 268435480
* This issue is observed when FTD is managed by Firepower Device Manager (FDM). * Security Zones configured in the ACP rules.
Contact TAC for Workaround
NA