Loading...
Nexus 3000 series switches are unable to configure the maximum SFLOW sampling rate of 1000000000 on 9.3.X Attempting a re-configuration on NXOS 9.3.X software revisions will result in the following error message: switch(config)# sflow sampling-rate 1000000000 sampling rate valid range : 4096 - 1000000000 If the configuration exists prior to upgrade, it will be preserved.
Issue discovered on N3K-C3132Q-XL running 9.3.X NXOS software revisions. Attempting to configure the maximum value for SFLOW sampling rate of 1000000000.
Use the maximum value of: sflow sampling-rate 16777215 -or- Down grade to 7.X revisions to re-configure the maximum value, and then upgrade back into 9.3.X revisions.
This issue has also been verified on an N9K-C9364D-GX2A running the affected releases.