FlexConnect APs from the same site tag drop from the controller and no Disjoin message is getting log. Instead the following error log is displayed on console: 2024/11/20 16:11:31.473174014 {wncd_x_R0-1}{1}: [errmsg] [17367]: UUID: 10000051b2361, ra: 5 (note): %CAPWAPAC_SMGR_TRACE_MESSAGE-5-AP_JOIN_DISJOIN: R0/1: wncd: AP Event: Mac: Session-IP: [5272] [5246] Number of messages(10001) in capwap queue is high. Limit : 10000. Message pending time : 126 seconds. Terminating capwap session
9800 WLC running 17.9.x onwards > APs in FlexConnect mode > APs connecting over WAN connection > Client performing multiple IPv6 address changes.
If possible, change APs to local mode.
The issue has been seen on networks deployed with FlexConnect Over The Top SDA environment.
The Cisco PSIRT has evaluated this issue and determined that it does not have a security impact that requires PSIRT ownership or involvement. This issue will be addressed via normal resolution channels. There is no PSIRT restriction that prohibits making this bug visible. If you believe that there is new information that would cause a change in the severity of this issue, please contact psirt@cisco.com for another evaluation. Additional information on Cisco's security vulnerability policy can be found at the following URL: https://sec.cloudapps.cisco.com/security/center/resources/security_vulnerability_policy.html