Upgrade hangs or fails in FMC tasks, one of the HA members becomes unresponsive
FP1120 in HA managed by FMC Upgrade from 7.3.1 to 7.4.1
When this issue occurs access the console of the device that is unresponsive and issue the boot command this will boot the device and complete the upgrade. Also would be beneficial to check the config register settings. if it's anything outside of default change it back using confreg 0x1
This issue only seems to occur with FP1120's in HA. Other upgrades seem to be unaffected at this time