Loading...
Loading...
Below kernel interface errors seen in the device during issue state Nov 12 04:24:56.551870 DSM10-0101-0629-17T1 ERR pmon#sensord: Error getting sensor data: pmbus/#1: Kernel interface error Nov 12 04:24:56.551870 DSM10-0101-0629-17T1 NOTICE pmon#sensord: sensor scan error (-1) PSU readings are not showing proper results. SHENGKAIWANG@PHX70-0101-1019-13T1:/var/log$ show platform psu PSU Model Serial HW Rev Voltage (V) Current (A) Power (W) Status LED ----- ------- -------- -------- ------------- ------------- ----------- -------- ----- PSU 1 N/A N/A N/A N/A N/A N/A OK green PSU 2 N/A N/A N/A N/A N/A N/A OK green
temporary glitch in AC input to the PSU causing a PSU flap.
workaround script reinitialize_psu.py shared with Customer to run the same whenever PSU goes into an inconsistent state. Fix provided in release 202305.1.0.8
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent