Loading...
Loading...
PNP process is logging to VTY 0, when this occurs the "authorization" line is removed from the VTY lines 0 - 4. After process logs out, the line is restored. When process logs in on VTY 1 and onwards, the configuration line is not removed. In other instances, the process logs in and never logs out, this causes the line to be removed from the configuration permanently. This issue was reported in C9300s and C3650s, using 16.12.x train. The switch doesn't report any logins from the process or changes done to the configuration.
PNP profile enabled locally on the switch PNP profile not used by external server or mis-configured. IOS-XE 16.12.x
Remove the PNP profile if not in use.
This issue causes the "authorization" line to be removed from lines VTY 0 - 4. Then, when an user tries to login to the switch, its commands are not authorized. Then the access is unavailable. The switch doesn't log anything related to config changes, nor in the logs or in the system traces.
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.