There is no time drift between parent Nexus 9K switch and the FEX as shown below: N9K# attach fex # Attaching to FEX # ... To exit type 'exit', to abort type '$.' fex-## show clock 08:41:49.127 CST Mon Feb 05 2024 fex-## exit /usr/bin/rlogin: Connection to 127.1.2.# closed normally. N9K# show clock 08:42:03.017 CST Mon Feb 05 2024 Time source is NTP FEX version: 7.0(3)I7(10) [Switch version: 7.0(3)I7(10)]
Data accuracy of "show logging log" and "show logging NVRAM" show future date as displayed below: `show logging log` 2024 Oct 17 18:56:12.536 %SATCTRL-FEX -2-SOHMS_DIAG_ERROR: FEX- System minor alarm on power supply 1: failed 2024 Oct 17 18:56:13.805 %SATCTRL-FEX -2-SOHMS_DIAG_ERROR: FEX- Module 1: Runtime diag detected major event: Voltage failure on power supply: 1 2024 Oct 17 18:56:13.810 %SATCTRL-FEX -2-SOHMS_DIAG_ERROR: FEX- System minor alarm on power supply 1: failed 2024 Oct 17 19:27:11.104 %SATCTRL-FEX -2-SOHMS_DIAG_ERROR: FEX- Recovered: From System minor alarm on power supply 1 `show logging nvram` 2024 Oct 17 18:56:12.536 %$ VDC-1 %$ %SATCTRL-FEX -2-SOHMS_DIAG_ERROR: FEX- System minor alarm on power supply 1: failed 2024 Oct 17 18:56:13.805 %$ VDC-1 %$ %SATCTRL-FEX -2-SOHMS_DIAG_ERROR: FEX- Module 1: Runtime diag detected major event: Voltage failure on power supply: 1 2024 Oct 17 18:56:13.810 %$ VDC-1 %$ %SATCTRL-FEX -2-SOHMS_DIAG_ERROR: FEX- System minor alarm on power supply 1: failed 2024 Oct 17 19:27:11.104 %$ VDC-1 %$ %SATCTRL-FEX -2-SOHMS_DIAG_ERROR: FEX- Recovered: From System minor alarm on power supply 1
None. Older release , recommendation to move to latest release.
FEX reloaded and recovered on its own with about a 40 second recovery time.
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.