This is corner case and Out of voltage minor alarm is not raised when user mimics Out of Voltage tests. 1) On Under voltage and Over voltage conditions simulation, no minor alarm is raised.
When Under voltage and Over voltage is applied by changing source voltage to test Out of Range values. This is corner case. The source voltage need to be manipulated to to set Under or Over voltage.
Under voltage and Over voltage, no Out of range minor is not raised.
None.
This is corner case and this is to test out of range voltage minor alarm by setting source voltage to Under or Over voltage according to Delta Standards. We can use the following command to check whether HW is raising an alarm or not. [node0_RP0_CPU0:~]$cpa_intf_envmon_test -e board_type=3,psu_inst=2,pmbus_cmd=0xe7,pmbus_size=5 board_type = 3 psu_inst = 2 pmbus_cmd = 0xe7 pmbus_size = 5 PSU in slot: 26 present: y Data = 0x0081001004