100G optics which use single lane [such as but not limited to QSFP-100G-LR-S and QSFP-100G-FR-S] show the correct output in the show interfaces transceiver detail output where they display just Lane 1 show interfaces Hu1/0/52 status Port Name Status Vlan Duplex Speed Type Hu1/0/52 connected 1 full 100G QSFP 100G FR-S ! show interfaces Hu1/0/52 transceiver detail ... Optical High Alarm High Warn Low Warn Low Alarm Transmit Power Threshold Threshold Threshold Threshold Port Lane (dBm) (dBm) (dBm) (dBm) (dBm) --------- ---- --------------- ---------- --------- --------- --------- Hu1/0/52 1 0.8 7.0 4.0 -2.0 -6.4 Optical High Alarm High Warn Low Warn Low Alarm Receive Power Threshold Threshold Threshold Threshold Port Lane (dBm) (dBm) (dBm) (dBm) (dBm) --------- ---- --------------- ---------- --------- --------- --------- Hu1/0/52 1 -7.6 7.5 4.5 -6.4 -10.4 However, when polled over SNMP, results for 4 lanes are presented: snmpwalk -v2c -c entPhysicalDescr ... ENTITY-MIB::entPhysicalDescr.1828 = STRING: QSFP 100GE FR-S ENTITY-MIB::entPhysicalDescr.1829 = STRING: Hu1/0/52 Module Temperature Sensor ENTITY-MIB::entPhysicalDescr.1830 = STRING: Hu1/0/52 Supply Voltage Sensor ENTITY-MIB::entPhysicalDescr.1831 = STRING: Hu1/0/52 Bias Current Sensor ENTITY-MIB::entPhysicalDescr.1832 = STRING: Hu1/0/52 Transmit Power Sensor ENTITY-MIB::entPhysicalDescr.1833 = STRING: Hu1/0/52 Receive Power Sensor ENTITY-MIB::entPhysicalDescr.1834 = STRING: Hu1/0/52 Tx Lane 1 Power Sensor ENTITY-MIB::entPhysicalDescr.1835 = STRING: Hu1/0/52 Tx Lane 2 Power Sensor ENTITY-MIB::entPhysicalDescr.1836 = STRING: Hu1/0/52 Tx Lane 3 Power Sensor ENTITY-MIB::entPhysicalDescr.1837 = STRING: Hu1/0/52 Tx Lane 4 Power Sensor ENTITY-MIB::entPhysicalDescr.1838 = STRING: Hu1/0/52 Rx Lane 1 Power Sensor ENTITY-MIB::entPhysicalDescr.1839 = STRING: Hu1/0/52 Rx Lane 2 Power Sensor ENTITY-MIB::entPhysicalDescr.1840 = STRING: Hu1/0/52 Rx Lane 3 Power Sensor ENTITY-MIB::entPhysicalDescr.1841 = STRING: Hu1/0/52 Rx Lane 4 Power Sensor snmpwalk -v2c -c entSensorValue ... CISCO-ENTITY-SENSOR-MIB::entSensorValue.1829 = INTEGER: 291 CISCO-ENTITY-SENSOR-MIB::entSensorValue.1830 = INTEGER: 32 CISCO-ENTITY-SENSOR-MIB::entSensorValue.1831 = INTEGER: 695 CISCO-ENTITY-SENSOR-MIB::entSensorValue.1832 = INTEGER: 8 CISCO-ENTITY-SENSOR-MIB::entSensorValue.1833 = INTEGER: -76 CISCO-ENTITY-SENSOR-MIB::entSensorValue.1834 = INTEGER: 8 CISCO-ENTITY-SENSOR-MIB::entSensorValue.1835 = INTEGER: -400 CISCO-ENTITY-SENSOR-MIB::entSensorValue.1836 = INTEGER: -400 CISCO-ENTITY-SENSOR-MIB::entSensorValue.1837 = INTEGER: -400 CISCO-ENTITY-SENSOR-MIB::entSensorValue.1838 = INTEGER: -76 CISCO-ENTITY-SENSOR-MIB::entSensorValue.1839 = INTEGER: -400 CISCO-ENTITY-SENSOR-MIB::entSensorValue.1840 = INTEGER: -400 CISCO-ENTITY-SENSOR-MIB::entSensorValue.1841 = INTEGER: -400
single-lane 100G transceiver Cat9500 switch polling ENTITY-MIB via SNMP for Digital Optical Monitoring [DOM] values
none practical other than silencing the alarms on NMS side
Cisco Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.