A Catalyst 9600 system configured in stackwise-virtual may not punt an L3 broadcast packet when the incoming interface is a port-channel member link that connects to the standby chassis in the stackwise-virtual. Ex: po1 member links are twe1/1/0/10 and twe2/1/0/10 where switch 1 is active. Problem would be observed if the broadcast comes in on twe2/1/0/10
This issue is seen on 17.3.7, did not see this issue on 16.x
Make incoming interface a standalone port on the standby chassis (issue not seen when the ingress link is not a port-channel member)