When Stackwise Virtual is configured with 2 supervisors per chassis with C9600X-SUP-2, the redundant / secondary / in-chassis standby supervisors should be in reset and should not form SSO. Quad-sup with this supervisor model is not supported as of this defect filing. But, they show SSO despite also showing in an "other" (reset / offline) state. Switch Number 1 Mod Ports Card Type Model Serial No. ---+-----+--------------------------------------+--------------+-------------- 1 48 48-Port 10GE / 25GE / 50GE C9600-LC-48YL AAA1234567AA 2 0 Blank Module C9600-SLOT-BLANK N/A 3 0 Supervisor 2 Module C9600X-SUP-2 AAA1234567AB 4 0 Supervisor 2 Module 5 0 Blank Module C9600-SLOT-BLANK N/A 6 0 Blank Module C9600-SLOT-BLANK N/A Mod MAC addresses Hw Fw Sw Status ---+--------------------------------+----+------------+------------------+-------- 1 689E.0B0D.C680 to 689E.0B0D.C6FF 1.1 17.10.1r 17.10.01 ok 3 88FC.5D8C.F700 to 88FC.5D8C.F77F 2.1 17.10.1r 17.10.01 ok 4 N/A N/A N/A N/A other <<<< other Mod Redundancy Role Operating Redundancy Mode Configured Redundancy Mode ---+-------------------+-------------------------+--------------------------- 3 Active sso sso 4 Active sso sso <<<< SSO Switch Number 2 Mod Ports Card Type Model Serial No. ---+-----+--------------------------------------+--------------+-------------- 1 48 48-Port 10GE / 25GE / 50GE C9600-LC-48YL AAA1234567BB 2 0 Blank Module C9600-SLOT-BLANK N/A 3 0 Supervisor 2 Module C9600X-SUP-2 AAA1234567BC 4 0 Supervisor 2 Module 5 0 Blank Module C9600-SLOT-BLANK N/A 6 0 Blank Module C9600-SLOT-BLANK N/A Mod MAC addresses Hw Fw Sw Status ---+--------------------------------+----+------------+------------------+-------- 1 DC77.4C29.8C00 to DC77.4C29.8C7F 1.1 17.10.1r 17.10.01 ok 3 88FC.5D8D.0280 to 88FC.5D8D.02FF 2.1 17.10.1r 17.10.01 ok 4 N/A N/A N/A N/A other <<<< other Mod Redundancy Role Operating Redundancy Mode Configured Redundancy Mode ---+-------------------+-------------------------+--------------------------- 3 Standby sso sso 4 Standby sso sso <<<<< SSO
C9600X-SUP-2 Build stackwise virtual pair with 2x supervisors per chassis
Remove secondary supervisors - quad-sup with RPR or SSO is not supported with this supervisor
Reference the High Availability Configuration Guide, Cisco IOS XE Dublin 17.11.x (Catalyst 9600 Switches), Chapter: Configuring Cisco StackWise Virtual "C9600X-SUP-2 on a C9606R chassis does not support Quad-Supervisor with RPR." Further note that inserting a secondary supervisor into an active stackwise virtual pair with this supervisor model may cause the system to hang. Reference Cisco Bug ID CSCwe18593.
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.