When Stackwise Virtual is configured with 2 supervisors per chassis with C9600X-SUP-2, the redundant / secondary / in-chassis standby supervisors should be in reset and should not form SSO. Quad-sup with this supervisor model is not supported as of this defect filing. But, they show SSO despite also showing in an "other" (reset / offline) state. Switch Number 1 Mod Ports Card Type Model Serial No. ---+-----+--------------------------------------+--------------+-------------- 1 48 48-Port 10GE / 25GE / 50GE C9600-LC-48YL AAA1234567AA 2 0 Blank Module C9600-SLOT-BLANK N/A 3 0 Supervisor 2 Module C9600X-SUP-2 AAA1234567AB 4 0 Supervisor 2 Module 5 0 Blank Module C9600-SLOT-BLANK N/A 6 0 Blank Module C9600-SLOT-BLANK N/A Mod MAC addresses Hw Fw Sw Status ---+--------------------------------+----+------------+------------------+-------- 1 689E.0B0D.C680 to 689E.0B0D.C6FF 1.1 17.10.1r 17.10.01 ok 3 88FC.5D8C.F700 to 88FC.5D8C.F77F 2.1 17.10.1r 17.10.01 ok 4 N/A N/A N/A N/A other <<<< other Mod Redundancy Role Operating Redundancy Mode Configured Redundancy Mode ---+-------------------+-------------------------+--------------------------- 3 Active sso sso 4 Active sso sso <<<< SSO Switch Number 2 Mod Ports Card Type Model Serial No. ---+-----+--------------------------------------+--------------+-------------- 1 48 48-Port 10GE / 25GE / 50GE C9600-LC-48YL AAA1234567BB 2 0 Blank Module C9600-SLOT-BLANK N/A 3 0 Supervisor 2 Module C9600X-SUP-2 AAA1234567BC 4 0 Supervisor 2 Module 5 0 Blank Module C9600-SLOT-BLANK N/A 6 0 Blank Module C9600-SLOT-BLANK N/A Mod MAC addresses Hw Fw Sw Status ---+--------------------------------+----+------------+------------------+-------- 1 DC77.4C29.8C00 to DC77.4C29.8C7F 1.1 17.10.1r 17.10.01 ok 3 88FC.5D8D.0280 to 88FC.5D8D.02FF 2.1 17.10.1r 17.10.01 ok 4 N/A N/A N/A N/A other <<<< other Mod Redundancy Role Operating Redundancy Mode Configured Redundancy Mode ---+-------------------+-------------------------+--------------------------- 3 Standby sso sso 4 Standby sso sso <<<<< SSO
C9600X-SUP-2 Build stackwise virtual pair with 2x supervisors per chassis
Remove secondary supervisors - quad-sup with RPR or SSO is not supported with this supervisor
Reference the High Availability Configuration Guide, Cisco IOS XE Dublin 17.11.x (Catalyst 9600 Switches), Chapter: Configuring Cisco StackWise Virtual "C9600X-SUP-2 on a C9606R chassis does not support Quad-Supervisor with RPR." Further note that inserting a secondary supervisor into an active stackwise virtual pair with this supervisor model may cause the system to hang. Reference Cisco Bug ID CSCwe18593.