Unexpected SC reloads observed on modular NCS 5500 devices: 0/RP0/ADMIN0:2022 Apr 16 12:31:08.957 GST: emon_proxy[2651]: %PKT_INFRA-FM-3-FAULT_MAJOR : ALARM_MAJOR :EMON detected EPC heartbeat failure to a card :DECLARE :0/SC0: Continue monitoring 0/RP0/ADMIN0:2022 Apr 16 12:31:09.043 GST: emon_proxy[2651]: %PKT_INFRA-FM-3-FAULT_MAJOR : ALARM_MAJOR :EMON detected EOBC heartbeat failure to a card :DECLARE :0/SC0: Continue monitoring 0/SC1/ADMIN0:2022 Apr 16 12:31:09.100 GST: esd-EPC-SW[2043]: %INFRA-ESD-6-PORT_STATE_CHANGE_LINK_UP : The physical link state of the control ethernet switch port 2 has changed. New Link state UP, Admin state: UP 0/SC1/ADMIN0:2022 Apr 16 12:31:09.105 GST: esd-EOBC-SW[2044]: %INFRA-ESD-6-PORT_STATE_CHANGE_ADMIN_UP : The admin state of the control ethernet switch port 24 has changed. New Admin state: UP, Link state UP 0/SC1/ADMIN0:2022 Apr 16 12:31:09.105 GST: esd-EOBC-SW[2044]: %INFRA-ESD-6-PORT_STATE_CHANGE_LINK_UP : The physical link state of the control ethernet switch port 24 has changed. New Link state UP, Admin state: UP 0/RP0/ADMIN0:2022 Apr 16 12:31:13.019 GST: emon_proxy[2651]: %PKT_INFRA-FM-3-FAULT_MAJOR : ALARM_MAJOR :EMON detected EPC heartbeat failure to a card :DECLARE :0/SC0: Continue monitoring
SC reloads occur during normal router operation
None at this point in time
- DDTS is raised to track occurrences and provide future enhancements - Impact is minor since in most NCS55xx deployments consist of redundant SC cards - CSCwf86232 was subsequently raised to provide enhanced debugging and a debug SMU to be installed at customer nodes for output collection during unexpected SC reload events.
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.