After firewall upgrade and fail-over test upstream to 9500-40x. UDLD enabled ports went into err-disabled state. UDLD disabled L3 routed port were up but not passing traffic causing BFD/ISIS to go down. Ping to directly connected devices on affected ports failed. Logs noticed on Fed traces 2023/04/13 13:26:14.097382374 {fed_F0-0}{1}: [fed] [15325]: UUID: 0, ra: 0, TID: 0 (note): CAD EPF draining: asic 0 core 1, port 0 context_id 11 is_nru 0 gal_mode 1 status 0 2023/04/13 13:26:14.097384621 {fed_F0-0}{1}: [fed] [15325]: UUID: 0, ra: 0, TID: 0 (note): AQM BUFFER: tla 0 asic 0 core 1 port35 queue 280 bufcnt 240
Issue seen on 9500-40x running version 17.3.4 9500-40x is configured as a collocated Border/Control plane node in SDA fabric. UDLD is enabled globally on the switch.
Reload the switch
N/A