Golden FPD on NCS540 cannot be upgraded in the field. It can only be upgraded in manufacturing or repair centre. Normally there should be no need to upgrade the Golden FPD during the product lifecycle. To avoid unnecessary alarms to customers, the Golden FPD version packaged into IOS XR rpm should never be ramped up. That way, FPD "Status" for Golden FPD will always show as "CURRENT". RP/0/RP0/CPU0:NCS540#sh hw-module fpd Auto-upgrade:Enabled Attribute codes: B golden, P protect, S secure FPD Versions ============== Location Card type HWver FPD device ATR Status Running Programd Reload Loc ------------------------------------------------------------------------------------------------- 0/RP0/CPU0 N540X-6Z18G-SYS-A 1.0 IoFpga CURRENT 0.17 0.17 0/RP0 0/RP0/CPU0 N540X-6Z18G-SYS-A 1.0 Prim-BootLoader CURRENT 20.04 20.04 0/RP0 0/RP0/CPU0 N540X-6Z18G-SYS-A 1.0 StdbyFpga S CURRENT 0.33 0.33 0/RP0 0/RP0/CPU0 N540X-6Z18G-SYS-A 1.0 TamFw S CURRENT 6.05 6.05 0/RP0 Location Card type HWver FPD device ATR Status Reqd Programd ------------------------------------------------------------------------------------------ 0/RP0/CPU0 N540X-6Z18G-SYS-A 1.0 IoFpgaGolden B MFG_UPGD_REQ 0.16 0.15 0/RP0/CPU0 N540X-6Z18G-SYS-A 1.0 StdbyFpgaGolden BS MFG_UPGD_REQ 0.33 0.32 0/RP0/CPU0 N540X-6Z18G-SYS-A 1.0 TamFwGolden BS CURRENT 6.05 6.05