Problem Description : Port went admin down after multiple reload Product : ASR920 TOPOLOGY : BGNPBGNPESR045 Te 0/0/10 ——— Ten 0/0/11 KLPIKLPIESR054 OBSERVATIONS : • On device KLPIKLPIESR054 port went to admin down state after 3 to 4 Power reloads. • No SFP change were done and activity of 1G to 10G SFP conversion activity performed. Same behaviour observed on multiple sites. • During issue state below are the port status.
2022/07/19 02:20:53.098 [parser] [17950]: UUID: 0, ra: 0 (note): CMD: 'dir nvram:startup-config | inc startup-config' 07:50:53 IST Tue Jul 19 2022 2022/07/19 02:20:53.233 [iosrp] [17950]: UUID: 0, ra: 0 (note): %HA_EM-6-LOG: Mandatory.dualrate_eem_policy.tcl: DUAL_RATE_CHANGE:Startup and running configuration are different. Ignoring write memory operation 2022/07/19 02:20:53.359 [parser] [17950]: UUID: 0, ra: 0 (note): CMD: 'enable' 07:50:53 IST Tue Jul 19 2022 2022/07/19 02:20:53.359 [iosrp] [17950]: UUID: 0, ra: 0 (note): 003040: Jul 19 07:50:53.359 IST: %PARSER-5-CFGLOG_LOGGEDCMD: User:unknown user logged command:!exec: enable 2022/07/19 02:20:53.632 [parser] [17950]: UUID: 0, ra: 0 (note): CMD: 'delete /force /recursive bootflash:dualrate_config/*' 07:50:53 IST Tue Jul 19 2022 2022/07/27 01:33:59.906 [parser] [18031]: UUID: 0, ra: 0 (note): CMD: ' carrier-delay up 2' 07:03:59 IST Wed Jul 27 2022 2022/07/27 01:33:59.906 [iosrp] [18031]: UUID: 0, ra: 0 (note): 000598: *Jul 27 07:03:59.905 IST: %PARSER-5-CFGLOG_LOGGEDCMD: User:vty0 logged command:carrier-delay up 2 2022/07/27 01:33:59.907 [parser] [18031]: UUID: 0, ra: 0 (note): CMD: ' carrier-delay down msec 0' 07:03:59 IST Wed Jul 27 2022 2022/07/27 01:33:59.907 [iosrp] [18031]: UUID: 0, ra: 0 (note): 000599: *Jul 27 07:03:59.907 IST: %PARSER-5-CFGLOG_LOGGEDCMD: User:vty0 logged command:carrier-delay down msec 0 2022/07/27 01:33:59.908 [parser] [18031]: UUID: 0, ra: 0 (note): CMD: ' shutdown' 07:03:59 IST Wed Jul 27 2022 2022/07/27 01:33:59.914 [iosrp] [18031]: UUID: 0, ra: 0 (note): 000600: *Jul 27 07:03:59.913 IST: %PARSER-5-CFGLOG_LOGGEDCMD: User:vty0 logged command:shutdown 2022/07/27 01:33:59.921 [iosrp] [18031]: UUID: 0, ra: 0 (note): 000602: *Jul 27 07:03:59.921 IST: %LINK-5-CHANGED: Interface TenGigabitEthernet0/0/10, changed state to administratively down
none so far
Cisco Integration
Learn more about where this data comes from
Bug Scrub Advisor
Streamline upgrades with automated vendor bug scrubs
BugZero Enterprise
Wish you caught this bug sooner? Get proactive today.