Loading...
Loading...
In current BGP EVPN implementation on Cat9k, in case when we have BUD node case (transit VTEP forwarding VXLAN traffic) and this device have configured L2 VNI, which state is currently down (for example, no interface associated with L2VNI vlan), BUM traffic sent over multicast group associated with L2 VNI will get dropped despite the fact that mroute table have interfaces present in the OIL list. This is caused due to fact, that local state on BUD node for L2 VNI in question is down. This enhancement should change this behavior in a way that even if BUD node local VNI state is down, traffic should still be forwarded to downstream devices. Workaround for this behavior is to un-configure L2 VNIs in down state or bring state of L2 VNI to up(for example, associate interface with L2VNI vlan). Also, this behavior will not be seen in case of unicast replication of BUM traffic.
L2 VNI with multicast replication in down state on BUD node
- un-configure L2 VNI in down state - bring state of L2 VNI to UP state - use unicast replication
Click on a version to see all relevant bugs