input errors keeps increasing on down links "not connected" TenGigabitEthernet2/1/3 is down, line protocol is down (notconnect) TenGigabitEthernet2/1/3 is down, line protocol is down (notconnect) Hardware is Ten Gigabit Ethernet, address is f8a7.3a56.e637 (bia f8a7.3a56.e637) MTU 9198 bytes, BW 10000000 Kbit/sec, DLY 10 usec, reliability 255/255, txload 1/255, rxload 1/255 Encapsulation ARPA, loopback not set Keepalive not set Auto-duplex, Auto-speed, link type is auto, media type is unknown input flow-control is on, output flow-control is unsupported . ARP type: ARPA, ARP Timeout 04:00:00 Last input never, output never, output hang never Last clearing of "show interface" counters 1d01h Input queue: 0/2000/0/0 (size/max/drops/flushes); Total output drops: 0 Queueing strategy: fifo Output queue: 0/40 (size/max) 5 minute input rate 0 bits/sec, 0 packets/sec 5 minute output rate 0 bits/sec, 0 packets/sec 0 packets input, 4131478 bytes, 0 no buffer Received 0 broadcasts (0 multicasts) 0 runts, 0 giants, 0 throttles 3868 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored < ------------ 0 watchdog, 0 multicast, 0 pause input 0 input packets with dribble condition detected 0 packets output, 0 bytes, 0 underruns Output 0 broadcasts (0 multicasts) 0 output errors, 0 collisions, 0 interface resets 0 unknown protocol drops 0 babbles, 0 late collision, 0 deferred 0 lost carrier, 0 no carrier, 0 pause output 0 output buffer failures, 0 output buffers swapped out TenGigabitEthernet1/1/4 is down, line protocol is down (notconnect) Hardware is Ten Gigabit Ethernet, address is 44b6.befe.9ab8 (bia 44b6.befe.9ab8) MTU 9198 bytes, BW 10000000 Kbit/sec, DLY 10 usec, reliability 255/255, txload 1/255, rxload 1/255 Encapsulation ARPA, loopback not set Keepalive not set Auto-duplex, Auto-speed, link type is auto, media type is unknown input flow-control is on, output flow-control is unsupported ARP type: ARPA, ARP Timeout 04:00:00 Last input never, output never, output hang never Last clearing of "show interface" counters 2d04h Input queue: 0/2000/0/0 (size/max/drops/flushes); Total output drops: 0 Queueing strategy: fifo Output queue: 0/40 (size/max) 5 minute input rate 0 bits/sec, 0 packets/sec 5 minute output rate 0 bits/sec, 0 packets/sec 0 packets input, 52084 bytes, 0 no buffer Received 0 broadcasts (0 multicasts) 0 runts, 0 giants, 0 throttles 98 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored < ---------- 0 watchdog, 0 multicast, 0 pause input 0 input packets with dribble condition detected 0 packets output, 0 bytes, 0 underruns Output 0 broadcasts (0 multicasts) 0 output errors, 0 collisions, 0 interface resets 0 unknown protocol drops 0 babbles, 0 late collision, 0 deferred 0 lost carrier, 0 no carrier, 0 pause output 0 output buffer failures, 0 output buffers swapped out + cosmetic bug , no impact + neither reload nor module reseat would stop the errors
C9300 with C9300-NM-8X running 16.12.5
no workarounds
issue narrowed down to wrong ASIC register programming , it is cosmetic and non impacting bug
Click on a version to see all relevant bugs
Cisco Integration
Learn more about where this data comes from
BugZero Plan
Streamline upgrades with automated vendor bug scrubs
BugZero Prevent
Wish you caught this bug sooner? Get proactive today.